Zobrazeno 1 - 10
of 169
pro vyhledávání: '"Erik Vilain Thomsen"'
Autor:
Mudabbir Tufail Bhatti, Borislav Gueorguiev Tomov, Søren Elmin Diedrichsen, Matthias Bo Stuart, Erik Vilain Thomsen, Jørgen Arendt Jensen
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a90d8733af65d874e6f986df238fbce6
https://doi.org/10.2139/ssrn.4462799
https://doi.org/10.2139/ssrn.4462799
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Martin Lind Ommen, Kitty Steenberg, Erik Vilain Thomsen, Borislav G. Tomov, Nathalie Sarup Panduro, Charlotte Mehlin Sorensen, Matthias Bo Stuart
Publikováno v:
Jensen, J A, Schou, M, Ommen, M L, Steenberg, K, Thomsen, E V, Tomov, B G, Panduro, N S, Sorensen, C M & Stuart, M B 2022, Synthetic Aperture High Quality B-mode Imaging with a Row-Column Array Compared to Linear Array Imaging . in Proceedings of 2022 IEEE International Ultrasonics Symposium . IEEE, 2022 IEEE International Ultrasonics Symposium, Venice, Italy, 10/10/2022 . https://doi.org/10.1109/IUS54386.2022.9957973
Row-column (RC) matrix probes can yield 3-Dvolumetric imaging using a number of receiving elements similarto traditional linear arrays for commercial scanners. Some doubtshave, however, been raised on the B-mode image quality ofRC probes. It is hypot
Publikováno v:
2022 IEEE International Ultrasonics Symposium (IUS)
Autor:
Iman Taghavi, Mostafa Amin-Naji, Mikkel Schou, Martin Lind Ommen, Kitty Steenberg, Niels Bent Larsen, Erik Vilain Thomsen, Jorgen Arendt Jensen
Publikováno v:
2022 IEEE International Ultrasonics Symposium (IUS).
Autor:
Niels Bent Larsen, Erik Vilain Thomsen, Martin Lind Ommen, Matthias Bo Stuart, Jihwan Youn, Jørgen Arendt Jensen
Publikováno v:
Youn, J, Ommen, M L, Stuart, M B, Thomsen, E V, Larsen, N B & Jensen, J A 2020, ' Detection and Localization of Ultrasound Scatterers Using Convolutional Neural Networks ', IEEE Transactions on Medical Imaging, vol. 39, no. 12, pp. 3855-3867 . https://doi.org/10.1109/TMI.2020.3006445
Delay-and-sum (DAS) beamforming is unable to identify individual scatterers when their density is so high that their point spread functions overlap. This paper proposes a convolutional neural network (CNN)-based method to detect and localize high-den
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Lasse Thurmann Jorgensen, Borislav G. Tomov, Matthias Bo Stuart, Marie Sand Traberg, Iman Taghavi, Sigrid Huesebo Oygaard, Martin Lind Ommen, Kitty Steenberg, Erik Vilain Thomsen, Nathalie Sarup Panduro, Michael Bachmann Nielsen, Charlotte Mehlin Sorensen
Publikováno v:
Jensen, J A, Schou, M, Jorgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Oygaard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sorensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Jensen, J A, Schou, M, Jørgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Øygard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sørensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, 9830770, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Jensen, J A, Schou, M, Jørgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Øygard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sørensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, 9830770, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article sum
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d1a139a50010404bebd1817b624c7df8
https://curis.ku.dk/portal/da/publications/anatomic-and-functional-imaging-using-rowcolumn-arrays(cd7494c5-36a5-4ee1-93da-9a89cbe0b554).html
https://curis.ku.dk/portal/da/publications/anatomic-and-functional-imaging-using-rowcolumn-arrays(cd7494c5-36a5-4ee1-93da-9a89cbe0b554).html
Autor:
Niels Bent Larsen, Erik Vilain Thomsen, Borislav Georgiev Tomov, Sigrid Husebo Oygard, Martin Lind Ommen, Matthias Bo Stuart, Soren Elmin Diederichsen, Jørgen Arendt Jensen
Capacitive micromachined ultrasonic transducers (CMUTs) have a nonlinear relationship between the applied voltage and the emitted signal, which is detrimental to conventional contrast enhanced ultrasound (CEUS) techniques. Instead, a three-pulse ampl
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a7a852502dbd65e7db5bdbd0cc15ba16
https://doi.org/10.21203/rs.3.rs-1085754/v1
https://doi.org/10.21203/rs.3.rs-1085754/v1
Publikováno v:
2021 IEEE International Ultrasonics Symposium (IUS).
The search for improved resolution in super-resolution ultrasound (SRUS) imaging leads to larger ultrasound arrays and smaller elements. A current large row-column addressed (RCA) array spans $\approx 21\times 21\ \text{mm}^{2}$ with $190 +190$ eleme
Autor:
Kitty Steenberg, Erik Vilain Thomsen
Publikováno v:
2021 IEEE International Ultrasonics Symposium (IUS)
This paper presents a new type of insulating substrate, polysilicon-on-quartz (POOQ), that can be used for wafer bonded capacitive micromachined ultrasonic transducers (CMUTs). The substrate is based on a quartz handle wafer on which a device layer o
Autor:
Mogens Jakobsen, Mathias J. G. Molgaard, Thomas Lars Andresen, Milan Laustsen, Erik Vilain Thomsen
Publikováno v:
Mølgaard, M J G, Laustsen, M, Jakobsen, M H, Andresen, T L & Thomsen, E V 2018, ' Combined colorimetric and gravimetric CMUT sensor for detection of benzyl methyl ketone ', Sensors and Actuators B: Chemical, vol. 275, pp. 483-489 . https://doi.org/10.1016/j.snb.2018.07.136
The detection of benzyl methyl ketone (BMK) is of interest as it is a common precursor for the synthesis of (meth)amphetamine. Resonant gravimetric sensors can be used to detect the mass and hereby the concentration of a gas while colorimetric arrays