Zobrazeno 1 - 5
of 5
pro vyhledávání: '"Eric J. Rainis"'
Publikováno v:
Journal of Orthopaedic Research. 26:1598-1604
The objective of this study was to determine the strain distribution in the inferior glenohumeral ligament at 0 degree, 30 degrees, and 60 degrees of external rotation with an anterior load applied to the joint. Five cadaver shoulders were dissected
Publikováno v:
Journal of applied physiology (Bethesda, Md. : 1985). 108(6)
Surgical repair of the glenohumeral capsule after dislocation ignores regional boundaries of the capsule and is not sex specific. However, each region of the capsule functions to stabilize the joint in different positions, and differences in joint la
Autor:
Heath B. Henninger, Steve A. Maas, Jeffrey A. Weiss, Richard E. Debski, Patrick J. McMahon, Eric J. Rainis
Publikováno v:
Journal of Biomechanical Engineering. 131
Inconclusive findings regarding the collagen fiber architecture and the material properties of the glenohumeral capsule make it unclear whether the material symmetry of the glenohumeral capsule is isotropic or anisotropic. The overall objective of th
Publikováno v:
Encyclopedia of Biomaterials and Biomedical Engineering, Second Edition ISBN: 9781420078039
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::89817b6190a03e6665854ccb8a1db1ff
https://doi.org/10.1081/e-ebbe2-120041715
https://doi.org/10.1081/e-ebbe2-120041715
Autor:
Richard E. Debski, Patrick J. McMahon, Carrie A. Voycheck, Eric J. Rainis, Elizabeth A. Timcho
Publikováno v:
ASME 2007 Summer Bioengineering Conference.
The glenohumeral joint is the most dislocated major joint in the body and the axillary pouch of the glenohumeral capsule is the primary stabilizer at the extreme ranges of external rotation. [1] Procedures to repair the capsule following dislocation