Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Eric Hensel"'
Autor:
Constanze Neupetsch, Eric Hensel, Andreas Heinke, Tom Stapf, Nico Stecher, Hagen Malberg, Christoph-Eckhard Heyde, Welf-Guntram Drossel
Publikováno v:
Sensors, Vol 23, Iss 14, p 6500 (2023)
The soft tissues of residual limb amputees are subject to large volume fluctuations over the course of a day. Volume fluctuations in residual limbs can lead to local pressure marks, causing discomfort, pain and rejection of prostheses. Existing metho
Externí odkaz:
https://doaj.org/article/e144de6d3e524cbfba76f867ba8d1a55
Autor:
Constanze Neupetsch, Eric Hensel, Burkhard Kranz, Welf-Guntram Drossel, Thomas Felderhoff, Christoph-Eckhard Heyde
Publikováno v:
Sensors, Vol 21, Iss 11, p 3821 (2021)
The wear comfort of a prosthesis is of great importance for amputee patients. The wear comfort can be affected by changes in the interface between the residual limb and prosthesis socket, which can be caused by time-dependent volume fluctuations of t
Externí odkaz:
https://doaj.org/article/d6f88375643d42069255e913a18f6d98
Publikováno v:
INTER-NOISE and NOISE-CON Congress and Conference Proceedings. 263:3933-3943
For transfer path analysis (TPA) methods, the description of the source is essential. The possibilities of source characterization are as different as the TPA methods. For the classical methods, the source is considered in the installed state with fe
Autor:
Thomas Felderhoff, Constanze Neupetsch, Eric Hensel, Burkhard Kranz, Christoph-Eckhard Heyde, Welf-Guntram Drossel
Publikováno v:
Sensors (Basel, Switzerland)
Sensors, Vol 21, Iss 3821, p 3821 (2021)
Sensors
Volume 21
Issue 11
Sensors, Vol 21, Iss 3821, p 3821 (2021)
Sensors
Volume 21
Issue 11
The wear comfort of a prosthesis is of great importance for amputee patients. The wear comfort can be affected by changes in the interface between the residual limb and prosthesis socket, which can be caused by time-dependent volume fluctuations of t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::da296e3216690d38fd145391040e4961
https://ul.qucosa.de/id/qucosa:85381
https://ul.qucosa.de/id/qucosa:85381
Publikováno v:
JOM. 70:321-327
Laser beam melting (LBM), an additive laser powder bed fusion technology, enables the structural integration of temperature-sensitive sensors and actuators in complex monolithic metallic structures. The objective is to embed a functional component in
Autor:
Eric Hensel, Peter Müller
Publikováno v:
Production Engineering. 11:655-664
The present paper deals with the experimental investigation of dynamic similarity laws of technical structures based on modal analyses of a reference and a scaled servo-screw press. At first, a brief introduction into the theoretical background is gi
Autor:
Constanze Neupetsch, Jan Troge, Sven Meißner, Eric Hensel, Welf-Guntram Drossel, Michael Werner, Christian Rotsch
Publikováno v:
Current Directions in Biomedical Engineering, Vol 5, Iss 1, Pp 343-345 (2019)
Vibration measurement and signal analysis methods are common to evaluate the functionality and characteristics of technical components in different industrial and scientific areas. Modal analysis for example is a standard method to characterize the d
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::509880c830d60caff3198941d94a5c2e
https://publica.fraunhofer.de/handle/publica/260562
https://publica.fraunhofer.de/handle/publica/260562
Autor:
Martin Burkhardt, Marco Lochmahr, Welf-Guntram Drossel, Sebastian Hensel, Matthias Nestler, Eric Hensel, Jan Troge
The gear whine phenomenon in vehicles is a well-known acoustic issue which often needs a development of individual measures. Especially in rear- wheel and four-wheel drive vehicles, the acoustical optimization of the rear axle leads to the major goal
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::37884057d1356f5488051ae35f039066
https://publica.fraunhofer.de/handle/publica/255134
https://publica.fraunhofer.de/handle/publica/255134
Publikováno v:
Biomedical Engineering / Biomedizinische Technik. 62