Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Erhan Ermek"'
Publikováno v:
PLoS ONE, Vol 11, Iss 8, p e0161611 (2016)
The role of hemodynamic forces within the embryo as biomechanical regulators for cardiovascular morphogenesis, growth, and remodeling is well supported through the experimental studies. Furthermore, clinical experience suggests that perturbed flow di
Externí odkaz:
https://doaj.org/article/3c84835b7935414cb57f12517749bbed
Autor:
Selda Goktas, Kerem Pekkan, Erhan Ermek, Merve Celik, Sercin Karahuseyinoglu, Cansu Karakaya, Ayşe İdil Çakıroğlu, S Samaneh Lashkarinia
In the embryonic heart, blood flow is distributed through a bilaterally paired artery system composed of the aortic arches (AAs). The purpose of this study is to establish an understanding of the governing mechanism of microstructural maturation of t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::11910531a5225ffe6855e6fc7c8cb9c0
https://aperta.ulakbim.gov.tr/record/7557
https://aperta.ulakbim.gov.tr/record/7557
Publikováno v:
Micro-computed Tomography (micro-CT) in Medicine and Engineering ISBN: 9783030166403
Micro-computed tomography (micro-CT) has its applications in various areas including bone structures, geological studies, and medical devices. This review focuses on cardiovascular applications of micro-CT and presents some of our cardiovascular devi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9d57a20684da92cb96c546490620782d
https://doi.org/10.1007/978-3-030-16641-0_11
https://doi.org/10.1007/978-3-030-16641-0_11
Publikováno v:
Biomechanics and modeling in mechanobiology. 19(5)
The microstructure for mature vessels has been investigated in detail, while there is limited information about the embryonic stages, in spite of their importance in the prognosis of congenital heart defects. It is hypothesized that the embryonic vas
Autor:
Naz Altekin, Samir Donmazov, Ahmet Arnaz, Gokce Nur Oguz, Senol Piskin, Kerem Pekkan, Erhan Ermek
Publikováno v:
Journal of Medical Devices
The hemodynamic energy loss through the surgically implanted conduits determines the postoperative cardiac output and exercise capacity following the palliative repair of single-ventricle congenital heart defects. In this study, the hemodynamics of s
Autor:
Kerem Pekkan, Can T. Capraz, Selda Goktas, Yusuf Ozgur Cakmak, Senol Piskin, Ozlem Yalcin, Erhan Ermek
Publikováno v:
Scientific Reports
Scientific Reports, Vol 7, Iss 1, Pp 1-9 (2017)
Scientific Reports, Vol 7, Iss 1, Pp 1-9 (2017)
Testicular artery torsion (twisting) is one such severe vascular condition that leads spermatic cord injury. In this study, we investigate the recovery response of a torsioned ram testicular artery in an isolated organ-culture flow loop with clinical
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::35d23c3b68e0160a7ded832e76a54333
http://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/3102
http://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/3102
Publikováno v:
PLOS One
PLoS ONE, Vol 11, Iss 8, p e0161611 (2016)
PLoS ONE
PLoS ONE, Vol 11, Iss 8, p e0161611 (2016)
PLoS ONE
The role of hemodynamic forces within the embryo as biomechanical regulators for cardiovascular morphogenesis, growth, and remodeling is well supported through the experimental studies. Furthermore, clinical experience suggests that perturbed flow di
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::38e101638d42d71184bf44a43a66063d
http://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/404
http://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/404
Publikováno v:
2015 International Conference on Optical MEMS and Nanophotonics (OMN).
Due to copyright restrictions, the access to the full text of this article is only available via subscription. Viscosity and density measurements in liquids in real-time is challenging. Previous MEMS based approaches use frequency sweeps for the purp
WOS: 000361408000016
We introduce a novel method for fast measurement of liquid viscosity and density using two cantilevers with different geometries. Our method can be used for real-time monitoring in lab on chip systems and offer high accuracy
We introduce a novel method for fast measurement of liquid viscosity and density using two cantilevers with different geometries. Our method can be used for real-time monitoring in lab on chip systems and offer high accuracy
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::79ed2ac512c7e877dcd4cbb6cddde0ce
https://hdl.handle.net/11480/3893
https://hdl.handle.net/11480/3893
Autor:
Göksenin Yaralıoğlu, Ibrahim Baris, Erhan Ermek, Selma Bulut, Onur Cakmak, Necmettin Kılınç, Hakan Urey, Ibrahim Halil Kavakli
Publikováno v:
Lab on a Chip
This paper proposes a MEMS-based sensor array enabling multiple clot-time tests for plasma in one disposable microfluidic cartridge. The versatile LoC (Lab-on-Chip) platform technology is demonstrated here for real-time coagulation tests (activated P