Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 71:1-7
n this article, a novel supply-voltage driving1 (SVDR) scheme for capacitive sensor front-ends is proposed to2 eliminate the parasitic capacitance effects. The suggested circuit3 is intended for remote sensors (and, hence, connected to the4 circuit t
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 69:2790-2797
This paper presents the design and implementation details of a complete noncontact (NC) voltage acquisition system, which allows the measurement of power-line voltage waveforms without galvanic contact. The system is composed by a novel capacitive pr
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 69:1682-1689
A high input impedance circuit to convert a single-ended (SE) voltage to its differential counterpart is proposed. It allows setting the common-mode (CM) output voltage to a reference voltage vR, while providing gain and a balanced output. The circui
Publikováno v:
Journal of Applied Geophysics. 205:104770
Here we present a novel electronic model of seismoelectric (SE) measurements. It allows to obtain the impedance seen by the electronic acquisition system while the SE effect is taking place. This i...
Publikováno v:
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Universitat Politècnica de Catalunya (UPC)
This article presents a novel front-end circuit for remote grounded capacitive sensors. The circuit is insensitive to amplifier input capacitance and stray interconnecting-cable capacitances. It does not rely on neutralization or compensation techniq
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ebf4b14ffe839adb17a3bf1c368ae3f7
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 67:1946-1953
A capacitive noncontact ac voltage measurement technique and its feasibility to measure arbitrary waveform signals are analyzed. The method provides self-calibration of the scale factor, an important feature considering the high variability that coup
Publikováno v:
IEEE Transactions on Biomedical Circuits and Systems. 12:437-445
This paper presents a novel two-wired active electrode that achieves ultrahigh input impedance using power supply bootstrapping. The proposed circuit reduces the input capacitance of a buffer amplifier while enabling measurements using leads with onl
Autor:
M. A. Bab, Alejandro Luis Veiga, S. A. González, Anna Roig, Paula A. Soto, P C Setton-Avruj, M. B. Fernández van Raap, D. F. Coral, Diego Muraca, Viviana C. Blank, G. P. Saracco, Enrique Mario Spinelli, Leonor P. Roguin
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
Magnetic hyperthermia is an oncological therapy where magnetic nanostructures, under a radiofrequency field, act as heat transducers increasing tumour temperature and killing cancerous cells. Nanostructure heating efficiency depends both on the field
Publikováno v:
International Journal of Reconfigurable and Embedded Systems (IJRES). 10:237
Real-time acquisition and processing of electroencephalographic signals have promising applications in the implementation of brain-computer interfaces. These devices allow the user to control a device without performing motor actions, and are usually
Publikováno v:
Energy Technology. 9:2100520