Zobrazeno 1 - 10
of 46
pro vyhledávání: '"Endothelial progenitor cell capture"'
Autor:
Jaya Chandrasekhar, Usman Baber, Samantha Sartori, Melissa B. Aquino, Petr Hájek, Borislav Atzev, Martin Hudec, Tiong Kiam Ong, Martin Mates, Borislav Borisov, Hazem M. Warda, Peter den Heijer, Jaroslaw Wojcik, Andres Iniguez, Zdeněk Coufal, Ahmed Khashaba, Muhammad Munawar, Robert T. Gerber, Bryan P. Yan, Paula Tejedor, Petr Kala, Houng Bang Liew, Michael Lee, Deborah N. Kalkman, George D. Dangas, Robbert J. de Winter, Antonio Colombo, Roxana Mehran
Publikováno v:
International Journal of Cardiology: Heart & Vasculature, Vol 31, Iss , Pp 100605- (2020)
Background: The COMBO stent is a biodegradable-polymer sirolimus-eluting stent with endothelial progenitor cell capture technology for faster endothelialization. Objective: We analyzed COMBO stent outcomes in relation to bleeding risk using the PARIS
Externí odkaz:
https://doaj.org/article/e55423582fb44594b38687802ca06541
Autor:
Sen-Tong Xiao, Chun-Yan Kuang
Publikováno v:
World Journal of Clinical Cases
Vascular injury is a frequent pathology in coronary artery disease. To repair the vasculature, scientists have found that endothelial progenitor cells (EPCs) have excellent properties associated with angiogenesis. Over time, research on EPCs has made
Autor:
Borislav Atzev, Petr Hájek, Martin Hudec, Pier Woudstra, Melissa Aquino, Zdeněk Coufal, Tiong Kiam Ong, Mascot, Roxana Mehran, Michael S. Lee, Martin Mates, Doreen Zeebregts, Karel T. Koch, Deborah N. Kalkman, Robbert J. de Winter, Peter den Heijer, Antonio Colombo, Hazem M. Warda, Jan G.P. Tijssen, Rishi Chandiramani, Vera C de Winter, Jaya Chandrasekhar, Borislav Borisov, Jarosław Wójcik, Marcel A.M. Beijk, Andrés Iñiguez, Remedee registry investigators, George Dangas, Samantha Sartori, Puk de Wilde, Usman Baber
Publikováno v:
Cardiovascular drugs and therapy / sponsored by the International Society of Cardiovascular Pharmacotherapy, 35(2), 309-320. Kluwer Academic Publishers
Purpose: The COMBO biodegradable polymer sirolimus-eluting stent includes endothelial progenitor cell capture (EPC) technology for rapid endothelialization, which may offer advantage in acute coronary syndromes (ACS). We sought to analyze the perform
Autor:
Antonio Colombo, Roxana Mehran, Borislav Atzev, Deborah N. Kalkman, Zdeněk Coufal, Houng Bang Liew, Petr Hájek, Muhammad Munawar, Samantha Sartori, Martin Hudec, Robbert J. de Winter, Martin Mates, Peter den Heijer, Hazem M. Warda, Usman Baber, Tiong Kiam Ong, Melissa Aquino, Robert Gerber, Birgit Vogel, Paula Tejedor, Andrés Iñiguez, George Dangas, Petr Kala, Bryan P. Yan, Ahmed Khashaba, Jaya Chandrasekhar, Borislav Borisov, Jarosław Wójcik, Michael S. Lee, Alexandr Schee
Publikováno v:
International journal of cardiology, 307, 17-23. Elsevier Ireland Ltd
Web of Science
Web of Science
Background The COMBO drug-eluting stent combines sirolimus-elution from a biodegradable polymer with an anti-CD34+ antibody coating for early endothelialization. Objective We investigated for geographical differences in outcomes after percutaneous co
Publikováno v:
JACC. Cardiovascular interventions. 13(7):820-830
Objectives: The aim of this study was to determine 1-year safety and efficacy after treatment with the COMBO and Orsiro stents. Background: The COMBO stainless-steel stent has an anti-CD34+ antibody coating to capture endothelial progenitor cells, th
Autor:
Borislav Atzev, Robert Gerber, Antonio Colombo, Martin Hudec, Peter den Heijer, Melissa Aquino, Muhammad Munawar, Usman Baber, Michael S. Lee, Bryan P. Yan, Roxana Mehran, Jan G.P. Tijssen, Karel T. Koch, Deborah N. Kalkman, Robbert J. de Winter, Andrés Iñiguez, Hazem M. Warda, George Dangas, Ahmed Khashaba, Pier Woudstra, Laura S.M. Kerkmeijer, Samantha Sartori, Petr Hájek, Tiong Kiam Ong, Jaya Chandrasekhar, Borislav Borisov, Jarosław Wójcik, Marcel A.M. Beijk, Martin Mates, Zdeněk Coufal
Publikováno v:
Catheterization and cardiovascular interventions, 97(5), 797-804. Wiley-Liss Inc.
Catheter Cardiovasc Interv
Catheter Cardiovasc Interv
BACKGROUND The COMBO drug eluting stent is a novel device with luminal endothelial progenitor cell capture technology for rapid homogeneous endothelialization. METHODS AND RESULTS We examined for sex differences in 1-year outcomes after COMBO stentin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d2868804ef26da8c5a698ed7e32e4d22
https://pure.amc.nl/en/publications/sex-differences-in-1year-clinical-outcomes-after-percutaneous-coronary-intervention-with-combo-stents-from-the-combo-collaboration(723aa2dc-d9e0-4e2c-9750-ec5ef3d0b709).html
https://pure.amc.nl/en/publications/sex-differences-in-1year-clinical-outcomes-after-percutaneous-coronary-intervention-with-combo-stents-from-the-combo-collaboration(723aa2dc-d9e0-4e2c-9750-ec5ef3d0b709).html
Autor:
Usman Baber, Moritz Blum, Jan G.P. Tijssen, Samantha Sartori, Karel T. Koch, Deborah N. Kalkman, Roxana Mehran, Melissa Aquino, Robbert J. de Winter, Antonio Colombo, Pier Woudstra, Jaya Chandrasekhar, Marcel A.M. Beijk, George Dangas
Publikováno v:
Catheterization and Cardiovascular Interventions
Catheterization and Cardiovascular Interventions, Wiley, 2020, ⟨10.1002/ccd.29270⟩
Catheterization and cardiovascular interventions, 98(6), 1095-1101. Wiley-Liss Inc.
Catheterization and Cardiovascular Interventions, Wiley, 2020, ⟨10.1002/ccd.29270⟩
Catheterization and cardiovascular interventions, 98(6), 1095-1101. Wiley-Liss Inc.
International audience; Background: Chronic kidney disease (CKD) patients undergoing percutaneous coronary intervention (PCI) experience greater ischemic events including clinically driven target lesion revascularization (CD-TLR). Whether the COMBO b
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b5965accfe22c8ae8820ec5a2e3712c3
https://hal.sorbonne-universite.fr/hal-02961217
https://hal.sorbonne-universite.fr/hal-02961217
Autor:
Cardiology, Graduate School, ACS - Atherosclerosis & ischemic syndromes, ACS - Heart failure & arrhythmias, ACS - Pulmonary hypertension & thrombosis
Publikováno v:
JACC. Cardiovascular interventions, 13(7), 820-830. Elsevier Inc.
Objectives: The aim of this study was to determine 1-year safety and efficacy after treatment with the COMBO and Orsiro stents. Background: The COMBO stainless-steel stent has an anti-CD34+ antibody coating to capture endothelial progenitor cells, th
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=narcis______::55661fc35ddc7b9e8620f3e7f2818a34
https://pure.amc.nl/en/publications/1year-clinical-outcomes-of-all-comers-treated-with-2-bioresorbable-polymercoated-sirolimuseluting-stents-propensity-scorematched-comparison-of-the-combo-and-ultrathinstrut-orsiro-stents(42e2a9c2-1547-48ae-9b33-358e304f24bf).html
https://pure.amc.nl/en/publications/1year-clinical-outcomes-of-all-comers-treated-with-2-bioresorbable-polymercoated-sirolimuseluting-stents-propensity-scorematched-comparison-of-the-combo-and-ultrathinstrut-orsiro-stents(42e2a9c2-1547-48ae-9b33-358e304f24bf).html
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.