Zobrazeno 1 - 4
of 4
pro vyhledávání: '"Elaine Lovelady"'
Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants
Publikováno v:
Journal of the Mechanical Behavior of Biomedical Materials, 77, pp. 616-623
Journal of the mechanical behavior of biomedical materials, 77, 616-623. Elsevier
Journal of the Mechanical Behavior of Biomedical Materials, 77, 616-623
Journal of the mechanical behavior of biomedical materials, 77, 616-623. Elsevier
Journal of the Mechanical Behavior of Biomedical Materials, 77, 616-623
The use of modular components in total hip arthroplasty introduced an additional interface with the potential for fretting and corrosion to occur. Fretting and corrosion at this interface have been reported as a potential cause of early failure of th
Publikováno v:
Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine
Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine, 231, 862-870
Proceedings of the Institution of Mechanical Engineers. Part H: Journal of engineering in medicine, 231(9), 862-870. Sage
Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine, 231, 9, pp. 862-870
Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine, 231, 862-870
Proceedings of the Institution of Mechanical Engineers. Part H: Journal of engineering in medicine, 231(9), 862-870. Sage
Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine, 231, 9, pp. 862-870
Item does not contain fulltext Fretting corrosion at the taper interface of modular hip implants has been implicated as a possible cause of implant failure. This study was set up to gain more insight in the taper mechanics that lead to fretting corro
Publikováno v:
Computer methods in biomechanics and biomedical engineering, 22(13), 1061-1072. Taylor & Francis
Computer Methods in Biomechanics and Biomedical Engineering, 22, 13, pp. 1061-1072
Computer Methods in Biomechanics and Biomedical Engineering, 22, 1061-1072
Computer Methods in Biomechanics and Biomedical Engineering, 22, 13, pp. 1061-1072
Computer Methods in Biomechanics and Biomedical Engineering, 22, 1061-1072
Contains fulltext : 208141.pdf (Publisher’s version ) (Open Access) Fretting and corrosion at the taper-head interface in total hip arthroplasty has been reported as a potential cause of early failure of the implant system. The finite element (FE)
Publikováno v:
Polym. Chem.. 2:559-562
Highly porous polymeric materials are prepared by thiol–ene and thiol–yne mediated network formation using high internal phase emulsion templates. The efficiency of network formation is between 80 and 90% for all materials while the thiol–yne m