Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Eder Issao Ishibe"'
Autor:
Eder Issao Ishibe
Publikováno v:
Biblioteca Digital de Teses e Dissertações da USPUniversidade de São PauloUSP.
Neste trabalho é apresentado o projeto de uma fonte de tensão de referência, um circuito capaz de prover uma tensão invariante com a temperatura, a tensão de alimentação e o processo de fabricação. São apresentadas: as equações de funcion
Autor:
Melania Aparecida Borges, Marcelo Prado, Tales Roberto de Souza Santini, Adriano Henrique Pereira Barbosa, Antonio Carlos Moreira, Eder Issao Ishibe, Marcelo Katz, Fatima Dumas Cintra
Publikováno v:
Einstein (São Paulo), Vol 17, Iss 2
ABSTRACT Objective To develop and test a beat-to-beat blood pressure monitoring device during coronary angiography, and compare it with invasive blood pressure monitoring. Methods Twenty-eight patients with an indication for hemodynamic study were se
Externí odkaz:
https://doaj.org/article/9eca4d5e03834f00958ea0d92f77f0f9
Autor:
Thyago Pereira Magnus, Miguel Almeida O. Filho, Elivane da Silva Victor, Marcelo Pires Prado, Alexandre R. Marra, Michael B. Edmond, Eder Issao Ishibe, Oscar Fernando Pavão dos Santos, Rodrigo Dias Rodrigues, Tales Santini
Publikováno v:
American Journal of Infection Control. 42:1188-1192
Background Monitoring of hand hygiene is an important part of the improvement of hospital quality indicators. Methods This study was prospectively performed over a 14-week (electronic observer) period from December 3, 2013-March 9, 2014, to evaluate
Autor:
Eder Issao Ishibe
Publikováno v:
Biblioteca Digital de Teses e Dissertações da USP
Universidade de São Paulo (USP)
instacron:USP
Universidade de São Paulo (USP)
instacron:USP
Neste trabalho é apresentado o projeto de uma fonte de tensão de referência, um circuito capaz de prover uma tensão invariante com a temperatura, a tensão de alimentação e o processo de fabricação. São apresentadas: as equações de funcion
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d0927db0886bdb7c36c79fb21fad7def
https://doi.org/10.11606/d.18.2014.tde-24072014-165540
https://doi.org/10.11606/d.18.2014.tde-24072014-165540
Publikováno v:
SBCCI
A bandgap reference voltage source with a temperature coefficient adjustment block was proposed. The bandgap topology employs current summation and the circuit was designed through metaheuristic algorithms in a 0.35-mm CMOS technology. Simulations wi
Publikováno v:
MWSCAS
A bandgap reference source with a temperature coefficient adjustment block was proposed. The topology employs current summation and the circuit was designed through a metaheuristic algorithm in a 0.35-um CMOS technology. Monte Carlo simulations show
Publikováno v:
ISCAS
A new circuit topology for bandgap reference voltage sources is proposed. The circuit works with current summation, has simple design characteristics, supports low voltage power supplies, and provides satisfactory stability, power consumption, and ar
Autor:
Antonio Carlos Moreira, Fátima Dumas Cintra, Eder Issao Ishibe, Marcelo Katz, Marcelo Pires Prado, Tales Santini, Adriano Henrique Pereira Barbosa, Melania Aparecida Borges
Publikováno v:
Einstein (São Paulo), Vol 17, Iss 2
einstein (São Paulo) v.17 n.2 2019
Einstein (São Paulo)
Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron:IIEPAE
Einstein
einstein (São Paulo) v.17 n.2 2019
Einstein (São Paulo)
Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron:IIEPAE
Einstein
Objective To develop and test a beat-to-beat blood pressure monitoring device during coronary angiography, and compare it with invasive blood pressure monitoring. Methods Twenty-eight patients with an indication for hemodynamic study were selected fo