Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Ed Mok"'
Publikováno v:
Physics in Medicine and Biology. 57:757-769
The Varian's new digital linear accelerator (LINAC), TrueBeam STx, is equipped with a high dose rate flattening filter free (FFF) mode (6 MV and 10 MV), a high definition multileaf collimator (2.5 mm leaf width), as well as onboard imaging capabiliti
Publikováno v:
Medical physics. 40(4)
To develop a fast and robust technique for the determination of optimized photon spectra for flattening filter free (FFF) beams to be applied in convolution/superposition dose calculations.A two-step optimization method was developed to derive optima
Publikováno v:
Medical physics. 39(10)
The dosimetric leaf gap (DLG) in the Varian Eclipse treatment planning system is determined during commissioning and is used to model the effect of the rounded leaf-end of the multileaf collimator (MLC). This parameter attempts to model the physical
Autor:
Daniel T. Chang, Lei Xing, James D. Murphy, Neville Eclov, K Kielar, Cullen M. Taniguchi, Todd F. Atwood, Claudia Christman-Skieller, Ed Mok, Albert C. Koong
Publikováno v:
International journal of radiation oncology, biology, physics. 85(4)
Purpose To determine how the respiratory phase impacts dose to normal organs during stereotactic body radiation therapy (SBRT) for pancreatic cancer. Methods and Materials Eighteen consecutive patients with locally advanced, unresectable pancreatic a
Publikováno v:
ICMLA (2)
This study was focused on a new beam source modeling technique for a flattening filter free (FFF) beam. The model was based on a previous three source model, and improved by introducing off axis ratio (OAR) of photon fluence to the primary and scatte
Publikováno v:
Medical physics. 38(4)
Purpose: With the introduction of flattening filter free (FFF) linear accelerators to radiation oncology, new analytical source models for a FFF beam applicable to current treatment planning systems is needed. In this work, a multisource model for th
Publikováno v:
Physics in medicine and biology. 43(12)
The purpose of this study was to investigate the application of the Monte Carlo technique to the calculation and analysis of output factors for electron beams used in radiotherapy. The code EGS4/BEAM was used to obtain phase-space files for 6, 12 and
Publikováno v:
Medical Physics. 40:041721
Purpose: To develop a fast and robust technique for the determination of optimized photon spectra for flattening filter free (FFF) beams to be applied in convolution/superposition dose calculations. Methods: A two-step optimization method was develop
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 42:207
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 39:351