Zobrazeno 1 - 10
of 14
pro vyhledávání: '"E.W. Kalkstein"'
Publikováno v:
IEEE Transactions on Industry Applications. 31:1402-1411
Autor:
E.A. Guro, F. Soudi, D.C. Blackburn, J.W. Stevens, J.T. Emery, E.W. Kalkstein, A. Pivec, M. Yalla, R. Zavadil, R. Hill, E. Gulachenski, W. Gish, P.W. Powell, G.J. Ball
Publikováno v:
IEEE Transactions on Power Delivery. 9:1325-1331
The special publication was prepared by the Power System Relaying Committee of the IEEE to assist people involved in the installation application, and operation of utility-interconnected dispersed storage and generation (DSG) systems of 500 kW or les
Autor:
E.W. Kalkstein, R. Ranjan
Publikováno v:
IEEE Transactions on Industry Applications. 30:164-169
A smart fuse that simulates conventional current limiting characteristics during high current faults and has the inherent intelligence to self monitor and the capability to be triggered from an external source has been developed. The smart fuse provi
Autor:
D.R. Hemming, R. W. Dempsey, E.A. Guro, T.L. Kaschalk, W. E. Feero, J.T. Emery, D.C. Dawson, E. J. Emmerling, G. Stranne, E.W. Kalkstein, B. Beckwith, J. Criss, R.J. Moran, R. W. Haas, R. W. Beckwith, E.A. Hauptmann, M. Hirakami, R. H. Jones, A.N. Darlington, G.W. Smith, D.C. Mikell
Publikováno v:
IEEE Transactions on Power Delivery. 5:924-929
A summary is presented of a special publication, 'Intertie Protection of Consumer-Owned Sources of Generation 3 MVA or Less', which has been recently prepared by the IEEE PES Power System Relaying Committee to assist people involved in the installati
Publikováno v:
Proceedings of IEEE Petroleum and Chemical Industry Technical Conference (PCIC '94).
One cause of serious injuries to electrical workers in the petrochemical industry is flash burns from arcing faults in medium voltage metalclad switchgear. First introduced in Europe, arc resistant switchgear designs are now being marketed in North A
Autor:
E.W. Kalkstein, R. Ranjan
Publikováno v:
[1992] Record of Conference Papers Industry Applications Society 39th Annual Petroleum and Chemical Industry Conference.
A smart fuse that simulates conventional current limiting characteristics during high current faults and has the inherent ability to self-monitor and the capability to be triggered from an external source has been developed. The smart fuse can be use
Publikováno v:
IEEE Transactions on Industry Applications. 25:750-765
Electrical studies are required to assure the proper integration of a gas-turbine cogeneration facility into an existing industrial-plant electrical system and the connected utility grid. Details of such a study are presented, including boundary-limi
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.