Publikováno v:
IEEE transactions on applied superconductivity : a publication of the IEEE Superconductivity Committee. 18(2)
This paper describes two general methods: field map processing and NMR lineshape analysis, that we are currently using for the on-going research of field improvement techniques specifically applied to our 700 MHz LTS/HTS NMR magnet. The validity of t
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
IEEE Transactions on Applied Superconductivity. 19:2281-2284
This paper addresses adverse effects of dimensional uncertainties of an HTS insert assembled with double-pancake coils on spatial field homogeneity. Each DP coil was wound with Bi2223 tapes having dimensional tolerances larger than one order of magni
Publikováno v:
IEEE Transactions on Applied Superconductivity. 17:1446-1449
As part of our 3-phase program to develop a high resolution 1 GHz LTS/HTS NMR magnet, a system composed of a 600 MHz LTS background NMR magnet and an HTS insert operating in the range 75 to 100 MHz has been built and tested. Operated at 4.2 K, immers
Publikováno v:
IEEE Transactions on Applied Superconductivity. 16:1531-1534
Phase II of our three phase program to develop a 1 GHz High Resolution LTS/HTS NMR Magnet, entails the design, construction and testing of a 700 MHz LTS/HTS NMR magnet. Here we report on the design and construction of a 100 MHz HTS Insert magnet, its
Publikováno v:
IEEE Transactions on Applied Superconductivity. 16:1535-1538
We report here on the status of our program aimed to build and operate a dry MRI magnet. The system incorporates a new design/operational concept that we believe it will be eventually adopted by manufacturers of the next generation of superconducting
Autor:
Seungyong Hahn, E.S. Bobrov, M. Tomsic, Juan Bascunan, Haigun Lee, Yukikazu Iwasa, M. Rindfleisch
Publikováno v:
IEEE Transactions on Applied Superconductivity. 16:1427-1430
Aiming to demonstrate feasibility and practicality of a low cost superconducting MRI magnet system targeted for use in small hospitals, rural communities and underdeveloped countries, MIT-Francis Bitter Magnet Laboratory has developed a 0.6 T/650 mm
Publikováno v:
IEEE Transactions on Appiled Superconductivity. 15:1299-1302
As a component of Phase-2 LTS/HTS NMR magnet of a 3-phase program to complete a 1-GHz LTS/HTS NMR magnet by 2009, an HTS insert magnet has been assembled from 48 double-pancake (DP) coils, each wound of high-strength Bi-2223/Ag/stainless steel compos
Publikováno v:
IEEE Transactions on Appiled Superconductivity. 13:1550-1553
A nuclear magnetic resonance (NMR) magnet comprised of low- and high-temperature superconducting (LTS/HTS) coils has been built and operated at a frequency of 360 MHz. The magnet operates at 4.2 K with the LTS background coil operated in persistent m