Autor:
A.-A. Edris, A.S. Mehraban, Laszlo Gyugyi, E.J. Stacey, Colin D. Schauder, B.A. Renz, A.J.F. Keri, L. Kovalsky
Publikováno v:
IEEE Transactions on Power Delivery. 14:1374-1381
The installation of the world's first unified power flow controller (UPFC) has been completed and a series of commissioning tests were conducted at the Inez Substation of American Electric Power (AEP) in eastern Kentucky. The project is a collaborati
Autor:
E.J. Stacey, L. Kovalsky, M.R. Lund, A.J.F. Keri, A.S. Mehraban, A.-A. Edris, Laszlo Gyugyi, Colin D. Schauder
Publikováno v:
IEEE Transactions on Power Delivery. 13:1530-1535
American Electric Power (AEP) has selected its Inez Substation in eastern Kentucky for the location of the world's first Unified Power Flow Controller (UPFC) installation. Comprising two /spl plusmn/160 MVA voltage-sourced GTO-thyristor-based inverte
Autor:
K.K. Sen, E.J. Stacey
Publikováno v:
IEEE Transactions on Power Delivery. 13:1453-1460
This paper describes the theory and the modeling technique of a flexible alternating current transmission systems (FACTS) device, namely, unified power flow controller (UPFC) using an Electromagnetic Transients Program (EMTP) simulation package. The
Autor:
A.-A. Edris, T.W. Cease, M. Gernhardt, Colin D. Schauder, T. Lemak, Laszlo Gyugyi, E.J. Stacey
Publikováno v:
IEEE Transactions on Power Delivery. 12:1805-1811
In 1995 a /spl plusmn/100 MVA static synchronous compensator (STATCON) was commissioned for the Tennessee Valley Authority (TVA) at the Sullivan substation in North-Eastern Tennessee, USA. This was an historic milestone in the initiative for flexible
Publikováno v:
IEEE Transactions on Power Delivery. 10:1486-1496
The availability of high power gate-turn-off (GTO) thyristors has led to the development of controllable reactive power sources, using electronic switching power converters, for use in power transmission systems. This new technology has resulted in e
Autor:
J.W. Porter, E.J. Stacey, J.-L. Wu, J.J. Bonk, P. G. Slade, Roy E. Voshall, L. Hong, W.F. Stubler
Publikováno v:
IEEE Transactions on Power Delivery. 7:507-515
The need for a distribution current limiting device (DCLD) by the utility industry is addressed. An evaluation was made of what specifications would be acceptable and what DCLD technique would fill the utilities' needs. Using this survey and a distri
Publikováno v:
Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.
The authors present results obtained from the testing of candidate 4500-V, 4000-A GTO (gate turn-off) thyristors for use in high-power inverters for electric utility application. Factors contributing to the voltage spike on turn-off are discussed wit
Publikováno v:
IEEE Transactions on Power Delivery. 3:1622-1627
The availability of large GTO thyristors has made advanced state VAr generators (ASVGs) competitive with their conventional counterparts. An ASVG substitutes silicon for large passive components. A description is given of a +or-1 MVAr prototype ASVG
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.