E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. 94:1072-1076
Single-pole switching and reclosing becomes of greater importance as the electrical utilities develop EHV and UHV transmission systems. While utilities continue to use the majority of the breakers on a three-pole basis, there exist areas wherein sing
Autor:
E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. 94:388-395
The three quantities are (1) residual fault current, (2) steady-state recovery voltage, and (3) natural frequency of transient recovery voltage. Loci of constant values of each of these, plotted in rectangular coordinates of degree of zero-sequence s
Autor:
E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :212-218
This paper introduces the concept that the surge impedance of a transmission line can be rapidly controlled by shunt compensation to make the corresponding surge impedance loading always equal to the actual loading. So doing prevents normal-frequency
Autor:
E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. 96:1608-1619
Various static devices for raising the stability limit of a power system are examined with respect to their employment at or near the electrical center of a two-machine system. Among these devices are series capacitors, shunt capacitors, combined ser
Autor:
E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. 95:219-230
This paper develops the joint use of several new concepts for improving stability, reliability, and safety of a double-circuit three-phase EHV line: 1. Use of selective-pole switching; that is, only the faulted conductors are opened and reclosed. 2.
Autor:
E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. 82:1050-1054
A simple and useful chart for showing the relations between electrical quantities on the a-c and d-c sides of a converter has loci of constant direct voltage and current in rectangular co-ordinates representing the active and reactive power of the a-
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :1273-1280
One transformer of a 1000-MVA 525/241.5-kV 60-Hz Y-connected bank of autotransformers, left connected to a 19-mi (30.5-km) 525-kV line but otherwise disconnected from the power system, was overheated after operating for nine minutes in ferroresonance
Autor:
E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :773-781
Changes in the network such as connecting shunt- resistor brakes, disconnecting generators or load, and inserting series capacitors, each rapidly accomplished under suitable control, can counteract other sudden, undesired changes in the network (shor
Fault Surge Versus Switching Surge A Study of Transient Overvoltages Caused by Line-to-Ground Faults
Autor:
Alvin C. Legate, E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :1762-1769
When the improvements in extra-high- oltage power circuit breakers now being studied are realized in practice, over- voltages caused by energization or reenergization of lines can be made so low that the limiting factor determining how much the line
Autor:
E. W. Kimbark
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :180-188
Improvement of transient stability of a 2-circuit ac transmission link by use of switched series capacitors is analyzed by equal-area diagrams for two kinds of disturbances: 1) a permanent fault on one ac circuit, cleared by opening a section of that