Zobrazeno 1 - 10
of 23
pro vyhledávání: '"E. V. Titovich"'
Autor:
E. M. Romanenkova, I. A. Eremina, E. V. Titovich, E. A. Sechko, L. V. Nikankina, V. A. Peterkova, O. B. Bezlepkina, D. N. Laptev
Publikováno v:
Сахарный диабет, Vol 25, Iss 2, Pp 155-165 (2022)
BACKGROUND: Type 1 diabetes mellitus (T1DM) is characterized by the development of absolute insulin deficiency. In some patients residual insulin secretion may persist for a long time. C-peptide is a widely used to measure the pancreatic beta cells f
Externí odkaz:
https://doaj.org/article/8bac16334d734164ba83b7c610883fb8
Autor:
M. N. Piatkevich, E. V. Titovich
Publikováno v:
Pribory i Metody Izmerenij, Vol 13, Iss 1, Pp 68-73 (2022)
The treatment planning process includes a review of the radiation treatment plan which leads to a decision on the patientʼs treatment technique. The scope of this study was to create a mathematical model for calculating of a radiation therapy sessio
Externí odkaz:
https://doaj.org/article/164fa1f52c1e4d0c9290a297cc8272b4
Autor:
D. N. Laptev, A. O. Emelyanov, E. A. Andrianova, L. I. Zilberman, I. A. Eremina, G. N. Svetlova, E. V. Titovich, O. B. Bezlepkina, V. A. Peterkova
Publikováno v:
Сахарный диабет, Vol 24, Iss 6, Pp 504-510 (2022)
BACKGROUND: In 2018, a Frestyle Libre flash glucose monitoring system (FGM) appeared in Russia and became a potential alternative to the traditional CGM. Studies carried out to date have shown the advantages of FGM over SMBG, but only a few of them r
Externí odkaz:
https://doaj.org/article/11c965ef837642ccb517c1bf34e242ff
Publikováno v:
Pribory i Metody Izmerenij, Vol 11, Iss 4, Pp 289-297 (2020)
One of the main factors affecting the effectiveness of radiation therapy is the constancy of the patient’s position on the treatment table created by immobilization devices of various designs and held throughout the entire irradiation procedure, wh
Externí odkaz:
https://doaj.org/article/12b9f89b64e74cecaa7ea5e2ad97214d
Publikováno v:
Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki, Vol 18, Iss 7, Pp 31-39 (2020)
Due to the rapid development and further improvement of radiation treatment technologies oncologists have an opportunity to precisely deliver individual dose distributions to the tumor, minimizing the doses obtained by critical organs and healthy str
Externí odkaz:
https://doaj.org/article/59783268e324482ab57db02abba36d67
Autor:
Y. I. Holdman, E. V. Titovich
Publikováno v:
Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki, Vol 0, Iss 7-8, Pp 133-140 (2019)
The rapid development of technologies in the field of radiation therapy allows us nowadays to implement precision and most clinically effective radiotherapy techniques for oncological patient’s treatment to minimize the irradiation of normal tissue
Externí odkaz:
https://doaj.org/article/0ec7b738032740e9b94f19af133bbea1
Publikováno v:
Pribory i Metody Izmerenij, Vol 8, Iss 1, Pp 73-80 (2017)
One of the main factors affecting the efficiency of oncology patients radiation therapy are time parameters (the amount of time that a patient spends in the therapy room) of the patient exposure session, because the patient treatment position depends
Externí odkaz:
https://doaj.org/article/54f836d4a2e34e04a06ed3a4cd2dfb42
Publikováno v:
Pribory i Metody Izmerenij, Vol 7, Iss 2, Pp 203-210 (2016)
To ensure the radiation protection of oncology patients is needed to provide the constancy of functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. For this purpose, their quality control procedure
Externí odkaz:
https://doaj.org/article/537a1ed67eb14cb99419a0c7bebcc7bb
Autor:
M. N. Piatkevich, E. V. Titovich
Publikováno v:
Proceedings of the National Academy of Sciences of Belarus, Physical-Technical Series. 67:239-249
The effectiveness of the use of modern technologies and methods of radiation treatment depends on the means of quality control of the operational parameters of the radiotherapy equipment. The development of technical means for verification of the rad
Publikováno v:
Proceedings of the National Academy of Sciences of Belarus, Physical-Technical Series. 67:119-128
A typical process for verification of treatment plans in intensity-modulated radiation therapy is described. The main errors and uncertainties that arise in the course of planning dose distribution and in the process of dose delivery are listed. Meth