Zobrazeno 1 - 10
of 129
pro vyhledávání: '"E. Kaisersberger"'
Autor:
E. Kaisersberger, Ekkehard Fueglein
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 120:23-31
Comparing own measurement values with the literature or textbook data is an established procedure for the correct interpretation, and final evaluation of the results obtained. For some spectroscopic measurement techniques such as mass spectrometry or
Autor:
Thorsten Streibel, E. Kaisersberger, Thomas Groeger, Markus Eschner, Thomas Denner, Ralf Zimmermann, Mohammad R. Saraji-Bozorgzad, Robert Geissler
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 105:859-866
A newly developed measurement technique for evolved gas analysis in thermogravimetry, viz. a thermo balance coupled to comprehensive gas chromatography/single photon ionization mass spectrometry (TG–GC × SPIMS), has been applied to investigate the
Autor:
Mohammad R. Saraji-Bozorgzad, Ralf Zimmermann, Thorsten Streibel, E. Kaisersberger, Thomas Denner
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 105:691-697
A commercial thermogravimetry—supersonic jet-skimmer quadrupole mass spectrometer system (TG-Skimmer-QMS, Netzsch GmbH, Germany) was successfully converted for soft single photon ionisation time-of-flight mass spectrometric (SPI-TOFMS) detection of
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 101:1189-1197
Multicycle Differential Scanning Calorimetry (MCDSC) is a procedure where repeated temperature cycles are executed and the measured data are superimposed for a selected number of cycles. Temperature cycles with a single sample are executed under sele
Autor:
Elena Moukhina, E. Kaisersberger
Publikováno v:
Thermochimica Acta. 492:101-109
For the desmearing of the DSC signal the mathematical function for the description of the instrument response with its time constants is necessary. The temperature dependence of the time constant was found from DSC measurements for melting of metals,
Autor:
Thorsten Streibel, R. Geißler, Mohammad R. Saraji-Bozorgzad, Thomas Denner, Ralf Zimmermann, E. Kaisersberger, Martin Sklorz
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 97:689-694
The potential of hyphenating thermogravimetry (TG) and soft photo ionisation mass spectrometry (EBEL-SPI-MS) for fundamental and applied research and material analysis has been demonstrated by a newly developed TG-SPI quadrupole MS coupling (TG-SPI-Q
Autor:
Marc Gonin, Bernhard M. Krooss, Alois Fendt, Mohammad R. Saraji-Bozorgzad, Thorsten Streibel, Robert Geissler, Ralf Zimmermann, Martin Sklorz, Katrin Fuhrer, Thomas Denner, E. Kaisersberger, T. Gröger
Publikováno v:
Analytical Chemistry. 81:6038-6048
Coupling thermal analysis (TA) with a subsequent analytical method in order to investigate evolved gaseous products from the thermal analysis is a well established method. A popular practice to analyze the gaseous products evolving from thermal analy
Autor:
R. Geißler, E. Kaisersberger, Ralf Zimmermann, Thomas Denner, Thorsten Streibel, Mohammad R. Saraji-Bozorgzad
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 96:813-820
A variety of crude oil samples have been investigated by the combined methods of thermal analysis and mass spectrometry by means of a newly developed prototype of a thermogravimetry—single photon ionisation time-of-flight mass spectrometer coupling
Autor:
R. Geißler, Mohammad R. Saraji-Bozorgzad, Thorsten Streibel, Martin Sklorz, Ralf Zimmermann, E. Kaisersberger, Thomas Denner
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 96:795-804
A combined thermogravimetry/differential scanning calorimetry device (TG/DSC) was coupled to single photon ionisation mass spectrometry (SPI-MS) for evolved gas analysis (EGA). Single photon ionisation (SPI) was performed with a new type of VUV light
Publikováno v:
Journal of Thermal Analysis and Calorimetry. 97:615-619
The combined analytical methods of thermal analysis and mass spectrometry have been applied in form of a newly developed prototype of a thermogravimetry — single photon ionisation time-of-flight mass spectrometer coupling (TG-SPI-TOFMS) to investig