Zobrazeno 1 - 10
of 38
pro vyhledávání: '"E. Hippert"'
Autor:
C.R.F. Azevedo, E. Hippert
This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis of IPT, in Brazil. Investigation revealed that most of the samples were not in accordance with ISO standards an
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b7857b6a95f2946f334acee9cc49c0f9
https://doi.org/10.31399/asm.fach.med.c9001690
https://doi.org/10.31399/asm.fach.med.c9001690
Autor:
E. Hippert, Claudio Ruggieri
Publikováno v:
Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual)
Universidade de São Paulo (USP)
instacron:USP
Universidade de São Paulo (USP)
instacron:USP
This work addresses a numerical investigation of the crack front fields and effects of crack-tip constraint in conventional fracture specimens with prescribed transverse delamination cracks. One purpose of this study is to conduct a systematic evalua
Publikováno v:
Engineering Failure Analysis. 9:621-633
The present paper summarises cases of metallurgical failure analysis of two femoral compression plates and one femoral nail-plate fabricated in stainless steel, one oral maxillo-facial plate for jaw reconstruction in commercially pure titanium alloy,
Autor:
C.R de Farias Azevedo, E Hippert
Publikováno v:
Engineering Failure Analysis. 9:265-275
The landing gear of an aircraft failed during its landing procedure due to the fracture of the outer cylinder, which is manufactured from an Al–5.7Zn–2.7Mg–0.5Mn–0.5Cu alloy. The material presented an oriented partially recrystallized microst
Publikováno v:
Engineering Failure Analysis. 9:1-15
The landing gear of an aircraft failed during landing due to the fracture of its outer cylinder attachment lug, which is manufactured from an aluminium alloy following British Specification DTD 5104 A. The material presented an oriented microstructur
Autor:
E. Hippert, C. R. F. Azevedo
Publikováno v:
Practical Failure Analysis. 1:53-61
This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis of IPT, in Brazil. Investigation revealed that most of the samples were not in accordance with ISO standards an
Publikováno v:
Engineering Failure Analysis; 2002, Vol. 9 Issue: 3 p265-275, 11p
Publikováno v:
Engineering Failure Analysis; 2002, Vol. 9 Issue: 1 p1-15, 15p
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.