Zobrazeno 1 - 10
of 27
pro vyhledávání: '"E. Elad"'
Publikováno v:
Chemical Engineering Transactions, Vol 21 (2010)
Abstract preview not available - see full-text PDF article.
Externí odkaz:
https://doaj.org/article/f92e211c5401467387fcaf4f7b4b7e57
Purpose: The aim of this study was to review the available literature from 1966 until December 31, 2010 and define clinical practice guidelines for the use of amifostine for the prevention and treatment of oral mucositis in cancer patients. Methods:
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______2127::8f37f588d6317641067f7eb96215c857
https://pergamos.lib.uoa.gr/uoa/dl/object/uoadl:3109718
https://pergamos.lib.uoa.gr/uoa/dl/object/uoadl:3109718
Purpose: The aim of this project was to review the available literature and define clinical practice guidelines for the use of anti-inflammatory agents for the prevention and treatment of oral mucositis in cancer patients. Materials and methods: A sy
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______2127::7c18f9a405433bc54f024d8a2f0ca54f
https://pergamos.lib.uoa.gr/uoa/dl/object/uoadl:3109316
https://pergamos.lib.uoa.gr/uoa/dl/object/uoadl:3109316
Publikováno v:
X-Ray Spectrometry. 6:21-29
The characteristics of commonly used trace element excitation methods are compared. Detection limits measured on four different instruments show that 15 kV broadband excitation is optimum for light element excitation, while monochromatic excitation i
Autor:
R. A. Sareen, E. Elad
Publikováno v:
IEEE Transactions on Nuclear Science. 21:75-84
The operation of ion implanted silicon position sensitive detectors at low temperatures will be described. The improved noise performance of the detector at these temperatures in both the energy and position modes will be analyzed and its implication
Publikováno v:
IEEE Transactions on Nuclear Science. 21:379-385
This paper describes the results of studies intended to provide a detailed understanding of the physical phenomena associated with dead layers sufficient to permit the production of rugged, reliable, ultrathin window detectors suitable for use in exp
Publikováno v:
IEEE Transactions on Nuclear Science. 20:534-544
This paper presents the results of dead-layer thickness measurements on silicon surface-barrier and ion-implanted detectors and a comparison of various methods for measuring dead-layer thicknesses. Our experimental arrangement and estimates of experi
Autor:
E. Elad
Publikováno v:
IEEE Transactions on Nuclear Science. 19:403-411
This paper describes a novel technique of charge restoration - the drain feedback, based on the characteristics of the gate-to-drain junction of the input FET. The restoration charge required at the input of the preamplifier is generated by impact io
Publikováno v:
IEEE Transactions on Nuclear Science. 17:354-362
The application of a high resolution semiconductor energy dispersive x-ray analyzer in scanning electron microscopy is described. Optimum specifications of an x-ray spectrometer for such application are outlined and various problems related to detect
Publikováno v:
Nuclear Instruments and Methods. 37:58-60
The paper describes a new approach to the design of linear gates which is based on “active action”. The described transistorized gate consists of a feedback amplifier whose loop gain is highly attenuated during the closed state of the gate. The c