Zobrazeno 1 - 10
of 221
pro vyhledávání: '"E. Aulhorn"'
Publikováno v:
Klinische Monatsblätter für Augenheilkunde. 202:116-125
The time for recovery of recognition of an optotype presented at a distance of 40 m subsequent to exposure to a flash gun (Eso company, Tettnang; flash energy 200 Ws, duration 1/1000 s; distance 10 m) was studied on 97 subjects aged 20 to 83 years. A
Publikováno v:
Klinische Monatsblatter fur Augenheilkunde. 202(2)
The time for recovery of recognition of an optotype presented at a distance of 40 m subsequent to exposure to a flash gun (Eso company, Tettnang; flash energy 200 Ws, duration 1/1000 s; distance 10 m) was studied on 97 subjects aged 20 to 83 years. A
Publikováno v:
Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 89(6)
A total of 173 eyes (visual field defect stages O-V) of 99 glaucoma patients were investigated by means of conventional threshold-oriented suprathreshold automated test point perimetry using the Tübingen Automatic Perimeter (TAP) and by means of whi
Publikováno v:
German journal of ophthalmology. 1(6)
The influence of the angle of inclination and tint of windshields on recognition distance was tested in 94 subjects aged 20-83 years. Both clear and tinted (heat-absorbing) windshields were tested. Light transmission (in the vertical position) was 90
Publikováno v:
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 229(1)
In a retrospective study, data from 116 patients suffering from different forms of retinitis pigmentosa were analysed, and 15 categories comprising altogether 34 symptoms or clinical signs were tabulated from each patient's record. The 15 categories
Publikováno v:
Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 88(5)
In 17 ocularly healthy persons the IOP was artificially raised by suction cup oculopression (negative pressure: 65 mmHg [8.67 kPa]) from initially 15.5 +/- 2.2 mmHg (2.07 +/- 0.29 kPa) to 25.2 +/- 4.0 mm Hg (3.36 +/- 0.53 kPa) (mean +/- SD). Continui
Publikováno v:
Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 88(5)
The treatment of optic neuritis (ON) with corticosteroids has been controversial for many years. None of the previous studies with the usual dosage of steroids or ACTH has proven that this therapy is beneficial. However, these studies did not apply s
Publikováno v:
Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 87(5)
In a total of 121 patients scotomata, detected by white-noise campimetry, were presented graphically in a standardized manner. The intensity of brightness and strength of motion ("noise") perception within the scotoma, as well as the reliability of t