Zobrazeno 1 - 10
of 34
pro vyhledávání: '"E-P. Suomalainen"'
Autor:
R. Martin, Gabriella Crotti, T. Cincar-Vujovic, R. Kampfer, Enrico Mohns, C. Mester, I. Blanc, A.J. Wheaton, Jan Hlavacek, M. Schnaitt, M. Hammarquist, Emil Dimitrov, H.E. van den Brom, W. Waldmann, Jari Hällström, Renata Styblikova, Karel Draxler, Gert Rietveld, H. Cayci, Fernando Garnacho, A. Bergman, B. Paczek, E-P. Suomalainen, G. Sadkowski
Publikováno v:
Draxler, K, Styblíková, R, Hlavacek, J, Rietveld, G, van den Brom, H E, Schnaitt, M, Waldmann, W, Dimitrov, E, Cincar-Vujovic, T, Paczek, B, Sadkowski, G, Crotti, G, Martin, R, Garnacho, F, Blanc, I, Kämpfer, R, Mester, C, Wheaton, A, Mohns, E, Bergman, A, Hammarquist, M, Çayci, H, Hällström, J & Suomalainen, E-P 2018, Results of an International Comparison of Instrument Current Transformers up to 10 kA at 50 Hz Frequency . in CPEM 2018-Conference on Precision Electromagnetic Measurements . IEEE Institute of Electrical and Electronic Engineers, Conference on Precision Electromagnetic Measurements, CPEM 2018, Paris, France, 8/07/18 . https://doi.org/10.1109/CPEM.2018.8500821
Traceability of the current ratio is crucial for the measurement of electrical energy in revenue metering. A comparison of the AC current ratio was therefore performed within EURAMET in the time period 2012 - 2016, using a precision CT as the traveli
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5dc64695d4a01930d35857de3a9f2bff
https://doi.org/10.1109/CPEM.2018.8500821
https://doi.org/10.1109/CPEM.2018.8500821
Publikováno v:
Meisner, J, Suomalainen, E-P, Hällström, J, Schmidt, M & Seifert, H 2016, Bilateral high voltage ac peak and rms value comparison up to 150 kV between VTT and PTB . in Precision Electromagnetic Measurements (CPEM 2016), 2016 Conference on . IEEE Institute of Electrical and Electronic Engineers, pp. 1-2, Conference on Precision Electromagnetic Measurements, CPEM 2016, Ottawa, Canada, 10/07/16 . https://doi.org/10.1109/CPEM.2016.7540801
This paper describes the measuring systems, setup and results of an rms and peak ac high voltage comparison performed at PTB in 2015. The three measuring systems are based on different principles. VTT system is a compressed gas capacitor based voltag
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8078070a1a05d99e66fdc6fa1f0fe210
https://cris.vtt.fi/en/publications/6370b7d7-2ed7-420e-ac94-2c01b3ba8b0d
https://cris.vtt.fi/en/publications/6370b7d7-2ed7-420e-ac94-2c01b3ba8b0d
Publikováno v:
2012 Conference on Precision electromagnetic Measurements.
Possibilities and limitations of using measurement system based on two sampling multimeters (DVM) for the ratio measurement of two impedances was investigated in MIKES. Calibration of a 1 µF capacitor from the quantized Hall resistance (QHR) was mad
Publikováno v:
CPEM 2010.
A comparison of inductance realisation at 100 mH was carried out in October –November 2009 at MIKES and SP. The measurand was a four terminal pair toroidal inductor measured at three frequencies 400 Hz, 1000 Hz and 1591 Hz. Realisations by series a
Autor:
E.-P. Suomalainen, Jari Hällström
Publikováno v:
Suomalainen, E-P & Hällström, J K 2009, ' Onsite calibration of a current transformer using a Rogowski Coil ', IEEE Transactions on Instrumentation and Measurement, vol. 58, no. 4, pp. 1054-1058 . https://doi.org/10.1109/TIM.2008.2007031
This paper describes an outdoor calibration of an instrument current transformer connected to 400 kV transmission line. The method of generation of the high current and the accuracy of calibration are discussed. The reference current measuring system
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::58595e7d90e95b81e067455b12933f6f
https://cris.vtt.fi/en/publications/5149c230-28d7-481b-b1f8-b7b4b1380fe8
https://cris.vtt.fi/en/publications/5149c230-28d7-481b-b1f8-b7b4b1380fe8
Autor:
E.-P. Suomalainen, Jari Hällström
Publikováno v:
Suomalainen, E P & Hällström, J 2008, An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data . in 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008 ., 4574808, IEEE Institute of Electrical and Electronic Engineers, pp. 372-373, 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008, Broomfield, CO, United States, 8/06/08 . https://doi.org/10.1109/CPEM.2008.4574808
In high voltage testing there is a need to measure both the peak value and rms value of power frequency voltage. This paper describes method to calculate accurately both quantities; even when the frequency is not stable. The method can handle wavefor
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8166ae068c494808cfe0790007330089
https://cris.vtt.fi/en/publications/ca0c7c68-16d2-4e5f-afea-9d3c8c805e2c
https://cris.vtt.fi/en/publications/ca0c7c68-16d2-4e5f-afea-9d3c8c805e2c
Publikováno v:
2004 Conference on Precision Electromagnetic Measurements.
The aim of the project was to compare the calibration capabilities for high valued capacitance (50 μF) and its losses at MIKES-HUT (Finland) and SP (Sweden). Comparison measurements were performed using 50 Hz alternating voltage of 10 V and 200 V. T
Publikováno v:
Bergman, A, Marx, R, Schon, K, Suomalainen, E P & Hällström, J 1999, Intercomparison of AC peak voltage measurement . in 1999 Eleventh International Symposium on High Voltage Engineering . vol. 1, Institution of Engineering and Technology IET, pp. 1.9.S1-1.12.S1, Proceedings of the 1999 11th International Symposium on 'High Voltage Engineering' (ish99), London, UK, 23/08/99 . https://doi.org/10.1049/cp:19990495
An intercomparison on the measurement of high voltage peak value has been carried out between the National Metrology Institutes of Sweden and Germany in 1995 and between Finland and Sweden in 1996. The results show a very satisfactory agreement betwe
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0c12493c48bc0664a531b55783624432
https://cris.vtt.fi/en/publications/8ff59497-3b54-46ce-8c7a-065d2fc36849
https://cris.vtt.fi/en/publications/8ff59497-3b54-46ce-8c7a-065d2fc36849
Autor:
Grzegorz Fusiek, Pawel Niewczas, Jari Hällström, E-P. Suomalainen, Jussi Havunen, John Nelson
Publikováno v:
University of Strathclyde
Fusiek, G, Nelson, J, Niewczas, P, Havunen, J, Suomalainen, E-P & Hällström, J 2017, Optical voltage sensor for MV networks . in IEEE SENSORS 2017 . IEEE Institute of Electrical and Electronic Engineers, 16th IEEE SENSORS Conference, ICSENS 2017, Glasgow, United Kingdom, 30/10/17 . https://doi.org/10.1109/ICSENS.2017.8234104
Fusiek, G, Nelson, J, Niewczas, P, Havunen, J, Suomalainen, E-P & Hällström, J 2017, Optical voltage sensor for MV networks . in IEEE SENSORS 2017 . IEEE Institute of Electrical and Electronic Engineers, 16th IEEE SENSORS Conference, ICSENS 2017, Glasgow, United Kingdom, 30/10/17 . https://doi.org/10.1109/ICSENS.2017.8234104
The design and construction of an optical voltage sensor (OVS) for distributed voltage measurements on medium-voltage (MV) networks (11 kV) is presented in this paper. The sensor prototype, comprising a piezoelectric transducer and a fiber Bragg grat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ccddb21f63713b6e81085432fe0adea2
https://pureportal.strath.ac.uk/en/publications/1b785285-e4d3-4def-9ab2-27606e8b5742
https://pureportal.strath.ac.uk/en/publications/1b785285-e4d3-4def-9ab2-27606e8b5742
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.