Autor:
C R, Blackwell, E C, McCullough
Publikováno v:
Medical physics. 19(1)
The same calibration grade ionization chamber and electrometer were sequentially sent to all five currently AAPM Accredited Dosimetry Calibration Laboratories (ADCL). A Cesium-137 based check device was utilized to ensure chamber and electrometer fac
Publikováno v:
Medical physics. 17(1)
A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a
Publikováno v:
Physics in Medicine and Biology. 19:831-842
A calorimeter has been used to measure the absorbed dose in tissue from a beam of fast neutrons. The calorimeter is of the twin type and is made of tissue-equivalent plastic. The calorimeter was calibrated electrically using the electrical resistivit
Autor:
J C Gore, E C McCullough
Publikováno v:
Physics in Medicine and Biology. 25:153-155
Publikováno v:
International journal of radiation oncology, biology, physics. 13(9)
In the setting of a large or irregularly shaped tumor, adjacent or intentionally overlapped intraoperative electron fields may be required to give adequate coverage of the intraoperative target volume. The matching of such intraoperative electron fie
Autor:
E. C. McCullough, J. L. Beach
Publikováno v:
Medical physics. 2(4)
An inexpensive recoil-proton counter telescope has been designed for absolute fluence measurements of a gas-target neutron source for radiation therapy. The detector has an absolute efficiency of 1.1 times 10-minus 9 at 20 cm from an isotropic source
Publikováno v:
Medical physics. 15(4)
The depth dependence (up to 25 cm) of the in-phantom wedge transmission factor (WTF) has been determined for three medical linear accelerator x-ray beams with energies of 4, 6, and 10 MV containing 15 degrees-60 degrees (nominal) brass wedges. All me
Autor:
J C, Gore, E C, McCullough
Publikováno v:
Physics in medicine and biology. 25(1)
Autor:
E C McCullough, J D Earle
Publikováno v:
Radiology. 144(2)
Dose distributions within the neck, resulting from equally weighted, parallel, opposed mantle fields, were measured using thermoluminescence dosimetry in using thermoluminescence dosimetry in an anthropomorphic phantom. Results show the similarity an
Determination of accurate dosimetric parameters for beveled intraoperative electron beam applicators
Autor:
R A, Dahl, E C, McCullough
Publikováno v:
Medical physics. 16(1)
Intraoperative electron beam therapy requires accurate dose maximum/monitor unit (Dmax/MU) values for both flat and beveled ended applicators (cones). Measurement of Dmax/MU values with either solid or nontilting scanning water systems may give rise