Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Durgam G. Chakrapani"'
Autor:
Durgam G. Chakrapani
Publikováno v:
Journal of Failure Analysis and Prevention. 22:2398-2402
Autor:
Durgam G. Chakrapani
A type 316 stainless steel pipe reducer section failed in service of bleached pulp stock transfer within 2 years in a pulp and paper mill. The reducer section fractured in the heat-affected zone of the flange-to-pipe weld on the flange side. The pipe
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5e79360d4dd894b43e76c19791090083
https://doi.org/10.31399/asm.fach.v01.c9001060
https://doi.org/10.31399/asm.fach.v01.c9001060
Autor:
Durgam G. Chakrapani
Cadmium-coated type 410 martensitic stainless steel 14-14 self-drilling tapping screws fractured during retorquing tests within a few weeks after installation. The screws were used to assemble structural steel frames for granite panels that formed th
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::8289445f3abff4954d06db65201322af
https://doi.org/10.31399/asm.fach.v01.c9001094
https://doi.org/10.31399/asm.fach.v01.c9001094
Autor:
Durgam G. Chakrapani
Several wires in aluminum conductor cables fractured within 5 to 8 years of, service in Alaskan tundra. The cables were comprised of 19-wire strands; the wires were aluminum alloy 6201-T81. Visual and metallographic examinations of the cold-upset pre
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ee3909df80133159af621de8f0fed9fa
https://doi.org/10.31399/asm.fach.v01.c9001124
https://doi.org/10.31399/asm.fach.v01.c9001124
Autor:
Durgam G. Chakrapani
Schedule 80 low-carbon steel pipes used to transfer kraft liquor in a Kamyr continuous pulp digester failed within 18 months after installation. Visual and metallographic examinations established that the cracking initiated on the internal surfaces o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e138f1f33ec3d216846e9f96bf97ba0d
https://doi.org/10.31399/asm.fach.v01.c9001061
https://doi.org/10.31399/asm.fach.v01.c9001061
Autor:
Durgam G. Chakrapani
A segment of a stainless steel clad bottom cone of an acid sulfite pulping batch digester failed from severe corrosion loss. The digester was fabricated of 19 mm (34 in.) low-carbon steel with 3.8 mm (0.15 in.) type 317L stainless steel cladding. The
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c5e9800da725712d61b867afbc043701
https://doi.org/10.31399/asm.fach.v01.c9001069
https://doi.org/10.31399/asm.fach.v01.c9001069