Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Duangthida Nonlhaopol"'
Autor:
Sirirat Tribuddharat, Thepakorn Sathitkarnmanee, Pornlada Sukhong, Maneerat Thananun, Parinda Promkhote, Duangthida Nonlhaopol
Publikováno v:
BMC Anesthesiology, Vol 21, Iss 1, Pp 1-8 (2021)
Abstract Background The Analgesia Nociception Index (ANI) has been suggested as a non-invasive guide for analgesia. Our objective was to compare the efficacy of ANI vs. standard pharmacokinetic pattern for guiding intraoperative fentanyl administrati
Externí odkaz:
https://doaj.org/article/029ad47b81ec42d486651f3e430bae6b
Autor:
Sirirat Tribuddharat, Thepakorn Sathitkarnmanee, Naruemon Vattanasiriporn, Maneerat Thananun, Duangthida Nonlhaopol, Wilawan Somdee
Publikováno v:
BMC Anesthesiology, Vol 20, Iss 1, Pp 1-7 (2020)
Abstract Background Sevoflurane is suitable for low-flow anesthesia (LFA). LFA needs a wash-in phase. The reported sevoflurane wash-in schemes lack simplicity, target coverage, and applicability. We proposed a one-step 1-1-8 wash-in scheme for sevofl
Externí odkaz:
https://doaj.org/article/3ffeb5a7355046d495ee154cc1d797b4
Autor:
Maneerat Thananun, Sirirat Tribuddharat, Thepakorn Sathitkarnmanee, Parinda Promkhote, Pornlada Sukhong, Duangthida Nonlhaopol
Publikováno v:
BMC Anesthesiology
BMC Anesthesiology, Vol 21, Iss 1, Pp 1-8 (2021)
BMC Anesthesiology, Vol 21, Iss 1, Pp 1-8 (2021)
Background The Analgesia Nociception Index (ANI) has been suggested as a non-invasive guide for analgesia. Our objective was to compare the efficacy of ANI vs. standard pharmacokinetic pattern for guiding intraoperative fentanyl administration. Metho
Autor:
Naruemon Vattanasiriporn, Duangthida Nonlhaopol, Maneerat Thananun, Sirirat Tribuddharat, Thepakorn Sathitkarnmanee, Wilawan Somdee
Publikováno v:
BMC Anesthesiology
BMC Anesthesiology, Vol 20, Iss 1, Pp 1-7 (2020)
BMC Anesthesiology, Vol 20, Iss 1, Pp 1-7 (2020)
Background Sevoflurane is suitable for low-flow anesthesia (LFA). LFA needs a wash-in phase. The reported sevoflurane wash-in schemes lack simplicity, target coverage, and applicability. We proposed a one-step 1-1-8 wash-in scheme for sevoflurane LFA
Autor:
Sirirat Tribuddharat, Thepakorn Sathitkarnmanee, Naruemon Vattanasiriporn, Maneerat Thananun, Duangthida Nonlhaopol, Wilawan Somdee
Background Sevoflurane is suitable for low-flow anesthesia (LFA). LFA needs a wash-in phase. The reported sevoflurane wash-in schemes lack simplicity, target coverage, and applicability. We proposed a one-step 1-1-8 wash-in scheme for sevoflurane-nit
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::1c5e0970e70917aceb07de1813e57a80
https://doi.org/10.21203/rs.2.407/v1
https://doi.org/10.21203/rs.2.407/v1
Autor:
Maneerat Thananun, Thepakorn Sathitkarnmanee, Sunchai Theerapongpakdee, Duangthida Nonlhaopol, Sirirat Tribuddharat, Siwalai Sucher
Publikováno v:
Medical Devices (Auckland, N.Z.)
Sunchai Theerapongpakdee,Thepakorn Sathitkarnmanee,Sirirat Tribuddharat,Siwalai Sucher,Maneerat Thananun,Duangthida Nonlhaopol Department of Anesthesiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand Background: The Lack’s circu
Autor:
Chakthip Suttinarakorn, Wilawan Somdee, Sirirat Tribuddharat, Maneerat Thananun, Duangthida Nonlhaopol, Thepakorn Sathitkarnmanee, Sunchai Theerapongpakdee
Publikováno v:
BioMed Research International
BioMed Research International, Vol 2014 (2014)
BioMed Research International, Vol 2014 (2014)
Background. We propose a 1-1-12 wash-in scheme for desflurane-nitrous oxide (N2O) low-flow anesthesia. The objective of our study was to determine the time to achieve alveolar concentration of desflurane (FAD) at 1, 2, 3, 4, 5, and 6%.Methods. We enr
Autor:
P. Bunsaengjaroen, Duangthida Nonlhaopol, Suhattaya Boonmak, Polpun Boonmak, S. Poomsawat, S. Srichaipanha
Publikováno v:
European Journal of Anaesthesiology. 24:664-667
To study the effect of 0.2 mg mL-1 of ondansetron added to morphine patient-controlled analgesia solution after a 4 mg loading dose on the incidence and severity of postoperative nausea and vomiting.One hundred and sixty patients scheduled for electi
1-1-12 one-step wash-in scheme for desflurane low flow anesthesia: performance without nitrous oxide
Autor:
Maneerat Thananun, Thepakorn Sathitkarnmanee, Wilawan Somdee, Duangthida Nonlhaopol, Sirirat Tribuddharat
Publikováno v:
Drug Design, Development and Therapy
Thepakorn Sathitkarnmanee, Sirirat Tribuddharat, Duangthida Nonlhaopol, Maneerat Thananun, Wilawan Somdee Department of Anesthesiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand Background: We reported a 1-1-12 wash-in scheme for
Autor:
Sunchai, Theerapongpakdee, Thanyathorn, Phanpanusit, Duenpen, Horatanaruang, Piyaporn, Bunsangjaroen, Prapapan, Limpkulwathanaporn, Maneerut, Thananun, Duangthida, Nonlhaopol
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 92(5)
Baby EAR circuit is a new modified enclosed afferent reservoir anesthetic breathing system for pediatric patients. By following His Majesty the King of Thailand's self-sufficiency philosophy, the circuit is simple and made of low-cost and easy-to-fin