Wenhao Chen, William J. Fisk, Robert Miller, Agatha Chang, Hugo Destaillats, Kazukiyo Kumagai, Sebastian Cohn, Meera Sidheswaran, Douglas P. Sullivan
Publikováno v:
Environmental Science & Technology. 47:5336-5343
Formaldehyde emissions from fiberglass and polyester filters used in building heating, ventilation, and air conditioning (HVAC) systems were measured in bench-scale tests using 10 and 17 cm(2) coupons over 24 to 720 h periods. Experiments were perfor
Autor:
Douglas P. Sullivan, Mark J. Mendell, Usha Satish, William J. Fisk, Siegfried Streufert, Toshifumi Hotchi, Krishnamurthy Shekhar
Publikováno v:
Environmental Health Perspectives
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other i
Autor:
Jean Sablayrolles, Douglas P. Sullivan, Laurent Molins, Hugo Destaillats, Catherine Jacquiod, Mohamad Sleiman
Publikováno v:
Applied Catalysis B: Environmental. 128:159-170
Photocatalytic oxidation (PCO) air cleaning is a promising technology suitable for the elimination of a broad range of volatile organic compounds (VOCs). However, performance of poorly designed PCO systems may be affected by the formation of volatile
Publikováno v:
Building and Environment. 47:357-367
This study explores the potential environmental and energy benefits of using activated carbon fiber (ACF) filters for air cleaning in HVAC systems. The parallel aims for the air cleaning system were to enable reduced indoor exposures to volatile orga
Publikováno v:
Applied Catalysis B: Environmental. 107:34-41
Appl. Catal. B – Environmental, 2011 Quantitative room-temperature mineralization of airborne formaldehyde using manganese oxide catalysts Meera A. Sidheswaran, Hugo Destaillats, Douglas P. Sullivan, Joern Larsen and William J. Fisk Environmental E
Publikováno v:
Journal of Asian Architecture and Building Engineering. 9:237-242
It is important to control outdoor airflow rates into HVAC systems in terms of energy conservation and healthy indoor environment. Technologies are being developed to measure outdoor air (OA) flow rates through OA intake louvers on a real time basis.
Autor:
Mark J. Mendell, Douglas P. Sullivan, Ekaterina A. Eliseeva, William J. Fisk, Wanyu R. Chan, Michael Spears, Sebastian Cohn
Publikováno v:
Mendell, MJ; Eliseeva, EA; Spears, M; Chan, WR; Cohn, S; Sullivan, DP; et al.(2015). A longitudinal study of ventilation rates in California office buildings and self-reported occupant outcomes including respiratory illness absence. Building and Environment, 92, 292-304. doi: 10.1016/j.buildenv.2015.05.002. Lawrence Berkeley National Laboratory: Retrieved from: http://www.escholarship.org/uc/item/3kf9397z
© 2015 Elsevier Ltd. Background: Limited evidence has associated lower ventilation rates (VRs) in offices with higher illness-related absence rates. Methods: We studied spaces in office buildings, selected without knowledge of their VRs, in three Ca
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::71a7b4a4581fb2769bc43bf57bfaa24c
https://escholarship.org/uc/item/3kf9397z
https://escholarship.org/uc/item/3kf9397z
Autor:
Man Pun Wan, Christopher Y.H. Chao, Douglas P. Sullivan, William J. Fisk, L. Zagreus, Tom Webster, David Faulkner
Publikováno v:
International Journal of Ventilation. 5:291-300
Underfloor air distribution (UFAD) is a new method of supplying heated or cooled air throughout a building. Reported advantages of UFAD include energy savings and improved indoor air quality (IAQ). We measured several aspects of the performance of an
Publikováno v:
Indoor Air. 9:273-281
In laboratory experiments, we investigated two task/ambient conditioning systems with air supplied from desk-mounted air outlets to efficiently ventilate the breathing zone of heated manikins seated at desks. In most experiments, the task conditionin