Zobrazeno 1 - 10
of 59
pro vyhledávání: '"Donald L. Bartel"'
Publikováno v:
Technometrics. 51:278-288
This article introduces a Bayesian methodology for the prediction for computer experiments having quantitative and qualitative inputs. The proposed model is a hierarchical Bayesian model with conditional Gaussian stochastic process components. For ea
Publikováno v:
Journal of Orthopaedic Research. 24:1384-1394
Wear mechanisms in polyethylene components for total knee replacements are inherently mechanical; the local stresses or strains exceed some material limit. Retrieval analysis and knee simulators have provided the means to quantify the damage observed
Autor:
Donald L. Bartel, Russell E. Windsor, Timothy M. Wright, Deirdre Campbell, Lance E. Peters, Jeremy J. Rawlinson
Publikováno v:
Clinical Orthopaedics and Related Research. 440:107-116
Modular augmented stems of a constrained condylar knee implant are intended to improve tibial fixation under increased varus/valgus loads, but conflicting studies have not yet indicated the factors determining stem usage and performance. To address t
Publikováno v:
Journal of biomechanical engineering. 138(8)
The normal knee joint maintains stable motion during activities of daily living. After total knee arthroplasty (TKA), stability is achieved by the conformity of the bearing surfaces of the implant components, ligaments, and constraint structures inco
Autor:
Thomas W. Belknap, Paul B. Chang, Donald L. Bartel, William I. Notz, Brian J. Williams, Thomas J. Santner, Kanwaljeet Singh Bawa Bhalla
Publikováno v:
Journal of Biomechanical Engineering. 123:239-246
Computer simulations of orthopaedic devices can be prohibitively time consuming, particularly when assessing multiple design and environmental factors. Chang et al. (1999) address these computational challenges using an efficient statistical predicto
Publikováno v:
Journal of Biomechanics. 32:1309-1318
A preclinical cost analysis method was introduced to assess the cost effectiveness of using a custom implant instead of standard “off-the-shelf” implants for revision total hip arthroplasty. Finite element models of proximal femur–implant syste
Publikováno v:
Clinical Orthopaedics and Related Research. 355:57-69
The effects of proximal bonding, distal stem geometry, and femoral neck length on cement and interface stresses were determined to understand better their role in clinical performance. The effects of stem design were compared with the effects of envi
Publikováno v:
Journal of Biomedical Materials Research. 43:241-248
The gamma radiation sterilization of ultrahigh molecular weight polyethylene (UHMWPE) components in air generates long-lived free radicals that oxidize slowly over time during shelf storage and after implantation. To investigate the combined effects
Publikováno v:
Journal of Orthopaedic Research. 16:80-88
The characterization of stress and deformation fields that incorporate moving cyclic loads and nonlinear material response in ultra-high molecular weight polyethylene components for total knee replacements is required to quantify mechanisms of surfac
Publikováno v:
Journal of Biomechanics. 30:639-642
Mechanical interactions between the polyethylene liner and the metal-backing play an important role in the load transfer and debris-generation mechanisms of an acetabular component. Insert thickness, cup orientation, and insert-shell interface condit