Zobrazeno 1 - 10
of 62
pro vyhledávání: '"Do-Young Moon"'
Publikováno v:
Applied Sciences, Vol 9, Iss 6, p 1241 (2019)
This study investigates the effects of hooked-end fiber geometry and volume fraction on the flexural behavior of concrete pedestrian decks. To achieve this, three different fiber geometries, i.e., three-dimensional (3D), four-dimensional (4D), and fi
Externí odkaz:
https://doaj.org/article/0c87f7fd24f5468d95768f95071fc52a
Autor:
Nur Indah Mukharromah, Do Young Moon
Publikováno v:
International Journal of Concrete Structures and Materials, Vol 18, Iss 1, Pp 1-15 (2024)
Abstract In typical steel fiber-reinforced concrete, the fibers are randomly distributed and oriented throughout the matrix, and a magnetic field can effectively align these randomly oriented fibers. To predict the extent to which the steel fibers co
Externí odkaz:
https://doaj.org/article/7785d8aba6904c749a94bd7c2a8c51b4
Publikováno v:
Journal of the Korean Society for Precision Engineering. 40:79-86
Publikováno v:
Journal of the Korea Concrete Institute. 34:597-607
Publikováno v:
Materials, Vol 14, Iss 4005, p 4005 (2021)
Materials
Volume 14
Issue 14
Materials
Volume 14
Issue 14
The effect of a magnetic field on the rheology of mortars with steel slags and fibers was evaluated in this study. The rheology of the mortar measured with and without a magnetic field was compared. The effect of steel fiber addition to normal and st
Publikováno v:
Numerical Models in Geomechanics
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a289871eef4ac17d4a706ad680b8ef80
https://doi.org/10.1201/9781003078548-114
https://doi.org/10.1201/9781003078548-114
Autor:
Do-Young Moon, Doo Yeol Yoo
Publikováno v:
Construction and Building Materials. 188:237-254
This study aims to investigate the implications of hooked-end steel fibers on the flexural performance of reinforced concrete (RC) beams with very low reinforcement ratios. For this, four different fiber volume fractions, vf, of 0.25%, 0.50%, 0.75%,
Effects of ageing and storage conditions on the interfacial bond strength of steel fibers in mortars
Publikováno v:
Construction and Building Materials. 170:129-141
The ageing effects on the interfacial bond strength of steel fibers in cement mortars, under different storage conditions, were investigated by performing single fiber pullout tests. The bond strength rapidly increased until the 28 days water curing.
Publikováno v:
Construction and Building Materials. 152:105-114
The paper investigated the effect of alkaline concrete environment on thermally damaged glass fiber reinforced polymer (GFRP) reinforcing bars through an accelerated aging test in alkaline solution. In the experimental test, the GRFP bar specimens we
Publikováno v:
Engineering Structures. 145:211-233
This study investigated the lateral load resistance performance of connection joint of a reinforced concrete (RC) wall structure connected to steel pipes. Four cases of connections were examined: a case where the anchor plate, which is a combination