Zobrazeno 1 - 10
of 25
pro vyhledávání: '"Djibo Sidikou A"'
Autor:
Retif, Paul, Djibo Sidikou, Abdourahamane, Waltener, Alexandre, Letellier, Romain, Al Salah, Anwar, Pfletschinger, Estelle, Taesch, Fabian, Verrecchia-Ramos, Emilie, Michel, Xavier
Publikováno v:
In Physica Medica April 2024 120
Autor:
Emilie Verrecchia-Ramos, Olivier Morel, Valérie Beauchat, Sylvie Denet, Abdourahamane Djibo Sidikou, Merwan Ginet, Estelle Pfletschinger, Luminita Teodor, Maud Trombowsky, Jeany Verdier, Christelle Vère, Paul Retif, Sinan Ben Mahmoud
Publikováno v:
EJNMMI Physics, Vol 10, Iss 1, Pp 1-12 (2023)
Abstract Background Patient radioprotection in myocardial perfusion imaging (MPI)-SPECT is important but difficult to optimize. The aim of this study was to adjust injected activity according to patient size—weight or BMI—by using a cardiofocal c
Externí odkaz:
https://doaj.org/article/514e227ddba54876bb44338c36cdc93d
Autor:
Paul Retif, Abdourahamane Djibo Sidikou, Christian Mathis, Romain Letellier, Emilie Verrecchia-Ramos, Rémi Dupres, Xavier Michel
Publikováno v:
Strahlentherapie und Onkologie. 198:907-918
Cranial stereotactic radiotherapy (SRT) requires highly accurate lesion delineation. However, MRI can have significant inherent geometric distortions. We investigated how well the Elements Cranial Distortion Correction algorithm of Brainlab (Munich,
Autor:
Verrecchia-Ramos, Emilie, Morel, Olivier, Beauchat, Valérie, Denet, Sylvie, Djibo Sidikou, Abdourahamane, Ginet, Merwan, Pfletschinger, Estelle, Teodor, Luminita, Trombowsky, Maud, Verdier, Jeany, Vère, Christelle, Retif, Paul, Mahmoud, Sinan Ben
Publikováno v:
EJNMMI Physics; 3/24/2023, Vol. 10 Issue 1, p1-12, 12p
Autor:
Retif, Paul, Djibo Sidikou, Abdourahamane, Mathis, Christian, Letellier, Romain, Verrecchia-Ramos, Emilie, Dupres, Rémi, Michel, Xavier
Publikováno v:
Strahlentherapie und Onkologie; Oct2022, Vol. 198 Issue 10, p907-918, 12p
Autor:
Emilie Verrecchia-Ramos, Romain Letellier, Paul Retif, Abdourahamane Djibo Sidikou, Philippe Quetin
Publikováno v:
Medical Physics
Medical Physics, American Association of Physicists in Medicine, 2021, 48 (7), pp.3453-3458. ⟨10.1002/mp.14841⟩
Medical Physics, American Association of Physicists in Medicine, 2021, 48 (7), pp.3453-3458. ⟨10.1002/mp.14841⟩
PURPOSE A common dosimetric quality assurance (QA) method in stereotactic body radiation therapy (SBRT) of lung tumors is to use lung phantoms with radiochromic film. However, in most phantoms, the film moves with the tumor, leading to the blurring e
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Physica Medica. 56:7-8
Introduction Delivery Analysis software uses the signal received from xenon detectors of Tomotherapy to calculate the MLC leafs open time (LOTs) and compares the measured sinogram with the planned one. We have used Delivery analysis for Tomotherapy p
Publikováno v:
Physica Medica. 68:22