Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Dirk Roelfs Meyer"'
Autor:
Thomas, Albrecht, Antonia, Ukrow, Michael, Werk, Gunnar, Tepe, Thomas, Zeller, Dirk-Roelfs, Meyer, Maren, Kutschera, Ulrich, Speck, Matthias, Waliszewski
Publikováno v:
CardioVascular and Interventional Radiology. 42:495-504
The principal objective of this pooled analysis was to investigate various patient and lesion characteristics on late lumen loss (LLL) after drug-coated balloon (DCB) angioplasty.Four randomized controlled trials (THUNDER, FEMPAC, PACIFIER, CONSEQUEN
Autor:
Peter Reimer, Marianne Brodmann, Michael R. Jaff, Illumenate Eu Rct Investigators, Karsten Krüger, Dirk-Roelfs Meyer, Henrik Schroeder, Martin Werner, Juan F. Granada
Publikováno v:
JACC: Cardiovascular Interventions. 11:2357-2364
Objectives The aim of this study was to assess the safety and effectiveness of a next-generation low-dose drug-coated balloon (DCB) designed to optimize the amount of drug transferred into the vessel wall and to maximize the amount of time the drug r
Autor:
Dirk-Roelfs Meyer, Klaus Brechtel, Elias Noory, Ulrich Beschorner, Thomas Albrecht, Thomas Zeller
Publikováno v:
Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 27(5)
Purpose: To evaluate the safety and efficacy of the novel SELUTION sustained-limus-release (SLR) drug-eluting balloon (DEB) in the treatment of femoropopliteal lesions. Materials and Methods: Between October 2016 and May 2017, 50 subjects (mean age 6
Autor:
Peter Reimer, Marianne Brodmann, Michael R. Jaff, Karsten Krüger, Henrik Schroeder, Dirk-Roelfs Meyer, Martin Werner
Publikováno v:
Circulation. 135:2227-2236
Background: Numerous studies have reported favorable outcomes using drug-coated balloons (DCBs) for treatment of symptomatic peripheral artery disease of the superficial femoral and popliteal arteries. However, the treatment effect compared with an u
Autor:
Marianne, Brodmann, Martin, Werner, Dirk-Roelfs, Meyer, Peter, Reimer, Karsten, Krüger, Juan F, Granada, Michael R, Jaff, Henrik, Schroeder
Publikováno v:
JACC. Cardiovascular interventions. 11(23)
The aim of this study was to assess the safety and effectiveness of a next-generation low-dose drug-coated balloon (DCB) designed to optimize the amount of drug transferred into the vessel wall and to maximize the amount of time the drug resides in t
Autor:
Thomas Albrecht, Dirk-Roelfs Meyer, Ilka Ott, Özlem Gögebakan, Catherine Roca, Stefan Müller-Hülsbeck, Matthias Waliszewski, Gunnar Tepe, Ines Gemeinhardt, Maciej Pech, Jörg Tautenhahn, Thomas Zeller, Zuhir Halloul, U. Redlich
Publikováno v:
Cardiovascular and interventional radiology. 41(7)
The previously reported 6-month angiographic and 12-month clinical outcomes of the CONSEQUENT trial demonstrated the safety and efficacy of a novel paclitaxel–resveratrol-coated balloon for the treatment of lesions in the femoropopliteal segment. T
Autor:
Beata Lux, Ferdinand Ruecker, Henrik Schroeder, Stephan H. Duda, Marcello Martorana, Dirk-Roelfs Meyer
Publikováno v:
Catheterization and Cardiovascular Interventions. 86:278-286
Objectives To assess the safety and effectiveness of the Stellarex™ drug-coated angioplasty balloon (DCB) to inhibit restenosis in the superficial femoral and/or popliteal artery. Background Treatment of peripheral arterial disease is challenged by
Autor:
Matthias Waliszewski, Thomas Albrecht, Antonia Ukrow, Thomas Zeller, Maren Kutschera, Ulrich Speck, Dirk-Roelfs Meyer, M. Werk, Gunnar Tepe
Publikováno v:
CardioVascular and Interventional Radiology. 42:1055-1055
In their recently published pooled analysis of four drug-coated balloon (DCB) studies, which focused on the impact of patient and lesion characteristics on LLL at 6 months (Albrecht T et al. Cardiovasc Intervent Radiol. 2018 Dec 11. https://doi.org/1
Autor:
Ulrich Dietz, Holger Hartmann, Mohammed Nabil Ahmed, Giuseppe Biondi Zoccai, Beatrix Schnorr, Christian Lange, H. Stiepani, Dirk Roelfs Meyer, Enrique Lopez Hänninen, M. Werk, Thomas Albrecht, Götz Eschenbach, Andrea Behne
Publikováno v:
Circulation: Cardiovascular Interventions. 5:831-840
Background— Peripheral percutaneous transluminal angioplasty is fraught with a substantial risk of restenosis and reintervention. A drug-eluting balloon (DEB) based on a novel coating was compared with uncoated balloons in patients undergoing femor
Publikováno v:
Journal of the American College of Cardiology. 72:B211
Most Drug Coated Balloons (DCB) typically transfer drugs with an excipient to the vessel wall during balloon expansion within minutes. By inventing a new technology sirolimus containing PLGA microspheres were attached to a balloon surface within a ph