Autor:
Deven L. Shinholt, Joshua T. Maze, Ryan T. Fellers, Bon Ikwuagwu, Steven C. Beu, Neil L. Kelleher, Kenneth R. Durbin, Philip D. Compton, Ping Yip, Rafael D. Melani, Danielle Tullman-Ercek, Bryan P. Early, Alexander Makarov, Michael W. Senko, Jared O. Kafader, Vlad Zabrouskov
Publikováno v:
Nature methods
A new Orbitrap-based ion analysis procedure is shown to be possible by determining the direct charge for numerous individual protein ions to generate true mass spectra. The deployment of an Orbitrap system for charge detection enables the characteriz
Autor:
Jared O. Kafader, Kenneth R. Durbin, Joshua T. Maze, Steven C. Beu, Michael W. Senko, Philip D. Compton, Neil L. Kelleher, Vlad Zabrouskov, Bon Ikwuagwu, Alexander Makarov, Ryan T. Fellers, Deven L. Shinholt, Ping Yip, Rafael D. Melani, Danielle Tullman-Ercek, Bryan P. Early
A new Orbitrap-based single ion analysis procedure is shown to be possible by determining the direct charge on numerous measurements of individual protein ions to generate true mass spectra. The deployment of an Orbitrap system for charge detection e
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::77d39eb3c811398cbc6f83efdba6be4c
https://doi.org/10.1101/715425
https://doi.org/10.1101/715425
Autor:
Ping Yip, Rafael D. Melani, Neil L. Kelleher, Michael W. Senko, Kenneth R. Durbin, Alexander Makarov, Philip D. Compton, Joshua T. Maze, Bryan P. Early, Deven L. Shinholt, Steven C. Beu, Vlad Zabrouskov, Jared O. Kafader
Publikováno v:
J Am Soc Mass Spectrom
Charge detection mass spectrometry (CDMS) of low-level signals is currently limited to the analysis of individual ions that generate a persistent signal during the entire observation period. Ions that disintegrate during the observation period produc
Publikováno v:
Analytical Chemistry. 87:10330-10337
Charge detection mass spectrometry (CDMS) is a single-particle technique where the masses of individual ions are determined from simultaneous measurement of each ion's mass-to-charge ratio (m/z) and charge. CDMS has many desirable features: it has no
Publikováno v:
International Journal of Mass Spectrometry. 371:1-7
We describe a simple electrospray interface incorporating a long drift region and a DC ion carpet. The function of the drift region is to thermalize and desolvate the ions. It has a series of ring electrodes supplied with RF and DC voltages, which ra
Publikováno v:
The journal of physical chemistry. A. 117(6)
The reactions of CO(2) on the Al(100)(+) cluster have been investigated as a function of cluster temperature (300-1100 K) and relative kinetic energy (0.2-10 eV). Two main products are observed at low cluster temperature: Al(100)O(+) (which is believ
Publikováno v:
Review of Scientific Instruments. 85:113109
Quadrupole mass filters (QMFs) are usually not used to analyze high m/z ions, due to the low frequency resonant circuit that is required to drive them. Here we describe a new approach to generating waveforms for QMFs. Instead of scanning the amplitud