Zobrazeno 1 - 10
of 23
pro vyhledávání: '"Dennise, Magill"'
Autor:
Summer L. Kaplan, Marc A. Felice, Keith J. Strauss, Dennise Magill, Rui Xiao, Xiaowei Zhu, Michael L. Francavilla
Publikováno v:
Journal of the American College of Radiology. 17:1698-1704
Autor:
Dennise Magill, Abass Alavi
Publikováno v:
PET Clinics. 15:293-298
The Image Gently Nuclear Medicine Working Group published a 10-year update in 2019. One of the future goals of this working group is to continue the efforts started in 2014 to harmonize the North American guidelines with the European Association of N
Publikováno v:
Quintessence international (Berlin, Germany : 1985). 51(6)
Commercial intraoral rectangular collimators are available for collimating to size 2 image receptor. The benefits of reducing the x-ray beam to match the area of the image detector in adult intraoral radiography are endorsed internationally. However,
Publikováno v:
Quintessence international (Berlin, Germany : 1985). 51(3)
Replacing conventional round intraoral collimators with rectangular collimators provides a considerable radiation dose reduction in adult patients. This study aimed to determine the radiation dose reduction via mathematical phantom when converting fr
Publikováno v:
Radiation Protection Dosimetry. 181:214-220
This study examines upper extremity skin contamination of nuclear medicine and radiation safety staff during 131I-Metaiodobenzylguanidine (MIBG) therapy. Utilizing retrospective data, a methodology for performing a rapid assessment of the radiation d
Publikováno v:
Pediatric Radiology. 48:227-234
Gonadal shielding remains common, but current estimates of gonadal radiation risk are lower than estimated risks to colon and stomach. A female gonadal shield may attenuate active automatic exposure control (AEC) sensors, resulting in increased dose
Publikováno v:
Dento maxillo facial radiology. 48(2)
OBJECTIVES: The objective of the study was to determine the radiation dose reduction achieved when rectangular collimation was used on various round collimators. In addition, we evaluated the tissue doses imparted to various head and neck organs. MET
To investigate the relationship in dental cone-beam CT (CBCT) between the manufacturer-reported image pixel data and a modified conversion to CT number densities in Hounsfield unit (HU).A standardized CT phantom was imaged using typical clinical para
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5bdf8d54858abc2a6aee06205510dda8
https://europepmc.org/articles/PMC5965908/
https://europepmc.org/articles/PMC5965908/
Publikováno v:
Radiation Protection Dosimetry. 156:436-444
The aim of the study was to investigate how differences in patient anatomy and CT technical factors in neck CT impact on thyroid doses and the corresponding carcinogenic risks. The CTDIvol and dose-length product used in 11 consecutive neck CT studie
Publikováno v:
Medical Physics. 38:3108-3113
PURPOSE To describe a method for estimating absorbed doses to the thyroid in patients undergoing neck CT examinations. METHODS Thyroid doses in anthropomorphic phantoms were obtained for all 23 scanner dosimetry data sets in the ImPACT CT patient dos