Zobrazeno 1 - 10
of 3 280
pro vyhledávání: '"Delta-wye transformer"'
Publikováno v:
2021 IEEE Energy Conversion Congress and Exposition (ECCE).
Grid emulators provide efficient manners to test grid-connected distributed power generators. They test the power generator such as photovoltaics, wind turbines without hardware damages. Recent studies investigated conventional voltage source inverte
Power transformers using a high temperature superconductor (HTS) ReBCO coated conductor and liquid nitrogen dielectric have many potential advantages over conventional transformers. The ac loss in the windings complicates the cryogenics and reduces t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::110b2a4041038136313ff19f2fb0ce40
https://doi.org/10.26686/wgtn.14331608.v1
https://doi.org/10.26686/wgtn.14331608.v1
Publikováno v:
2020 Conference on Precision Electromagnetic Measurements (CPEM).
A self-calibrating current transformer with nominal ratio 10 A to 100 mA, intended for low frequencies applications, was developed. It has 100 independent primary windings to be connected in series or parallel, so that it can be configured as 100:1 o
Publikováno v:
IEEE Transactions on Power Delivery. 33:2061-2069
The commercial application of conventional unified power flow controllers (UPFCs) is rare, because of their high installation and operational costs. Sen proposed the “Sen” transformer (ST) that provides similar power flow control functionality as
Publikováno v:
IEEE Transactions on Power Electronics. 33:7545-7557
This paper presents a high-frequency modular medium-voltage AC (4160 VAC or 13.8 kVAC) to low-voltage DC (400 VDC) system that is scalable in order to be used for different scale microgrids. A 15 kW, 500 kHz DC/DC converter is demonstrated as the mos
Publikováno v:
Ekhtiari, M, Zsurzsan, T-G, Andersen, M A E & Zhang, Z 2017, ' Optimum phase shift in the self-oscillating loop for piezoelectric transformer-based power converters ', I E E E Transactions on Power Electronics . https://doi.org/10.1109/TPEL.2017.2771297
BASE-Bielefeld Academic Search Engine
BASE-Bielefeld Academic Search Engine
A new method is implemented in designing of self-oscillating loop for driving piezoelectric transformers. The implemented method is based on combining both analog and digital control systems. Digitally controlled time delay through the self-oscillati
Autor:
L. Satish, Pritam Mukherjee
Publikováno v:
IEEE Transactions on Power Delivery. 33:1620-1627
A novel indirect measurement method to estimate the equivalent air-core inductance of an iron-cored transformer winding is proposed. The method utilizes frequency response analysis (FRA) magnitude data to estimate this quantity. Its implementation in
Autor:
Hao Chen, Deepak Divan
Publikováno v:
IEEE Transactions on Power Electronics. 33:5724-5738
The soft-switching solid-state transformer (S4T) employs only 12 main active devices and an auxiliary resonant circuit to implement a bidirectional solid-state transformer, with an attractive feature of achieving a full range of zero-voltage-switchin
Publikováno v:
IEEE Transactions on Power Delivery. 33:1035-1043
Precise localization of partial discharge (PD) inside a power transformer winding is a challenging task. Previously, researchers have used internal calibration or reference signals to locate the PD source. The location of any arbitrary (test) PD sour
Publikováno v:
IEEE Transactions on Power Delivery. 33:610-619
Current transformer (CT) saturation can cause the maloperation of transformer differential protection under external faults. To avoid this problem, a method based on the histogram of the normalized rotated current (NRC) is proposed. NRC is obtained b