Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Debra L Zarro"'
Publikováno v:
Perfusion. 17:9-14
An investigation was conducted to compare several variables of off-pump coronary artery bypass (OPCAB) procedures with those using cardiopulmonary bypass (CPB) for myocardial revascularization by two surgeons. The patients were divided into four grou
Autor:
Patricia A Gustafson, Norman J Manley, Debra L Zarro, Ralph M Montesano, Barbara-Anne Elmore, Michael Quinn, Joseph M Castagna, David A Palanzo
Publikováno v:
Perfusion. 16:279-283
An investigation was conducted to evaluate the effect that surface coating of the hollow-fiber membrane oxygenator had on circulating platelet count drop during cardiopulmonary bypass (CPB). Sixty patients undergoing non-emergency myocardial revascul
Publikováno v:
Perfusion. 16:129-135
An investigation was conducted to determine whether adding albumin to the prime of the cardiopulmonary bypass circuit had any effect on postoperative weight gain. Patients undergoing non-emergency myocardial revascularization for coronary artery dise
Autor:
Michael Quinn, Patricia A Gustafson, Joseph M Castagna, Norman J Manley, David A Palanzo, Ralph M Montesano, Debra L Zarro, Barbara-Anne Elmore
Publikováno v:
Perfusion. 14:473-479
The new Trillium™ Biopassive Surface is a coating designed to minimize the adsorption of protein and the attachment of cells. In previous studies, we were able to demonstrate that, by coating the bypass circuit with small amounts of albumin, the dr
Publikováno v:
Perfusion. 13:145-150
Adenosine is an endogenous nucleotide and a breakdown product of adenosine triphosphate. Adenosine has been proposed as a mediator of the ischaemic preconditioning phenomenon. Ischaemic reperfusion injury incurred during and following cardiopulmonary
Autor:
Norman J Manley, Patrick C Meloy, David A Palanzo, Michael Quinn, Barbara-Anne Elmore, Ralph M Montesano, Debra L Zarro, Patricia A Gustafson
Publikováno v:
Perfusion. 11:481-485
A prospective study was conducted to evaluate the trans-oxygenator pressure gradient across three different hollow-fibre membrane oxygenators during routine cardiopulmonary bypass (CPB). Sixty consecutive open-heart surgery patients were randomly div
Autor:
Debra L Zarro, David A Palanzo
Publikováno v:
Perfusion. 11:451-453
With the push to get patients through the system in five days, most patients undergoing nonemergency coronary artery bypass grafting (CABG) are being 'fast-tracked'. Using this anaesthetic regimen appears to keep patients less anaesthetized (light) d
Autor:
Ralph M Montesano, Joseph M Castagna, Debra L Zarro, Patricia A Gustafson, Michael Quinn, David A Palanzo, Norman J Manley, Barbara-Anne Elmore
Publikováno v:
Perfusion. 17(2)
Continuous insulin infusion was not an effective mode of treatment in maintaining safe blood glucose levels (
Publikováno v:
Perfusion. 14(3)
Previous studies have demonstrated high transoxygenator pressures with noncoated hollow-fiber membrane oxygenators. These reports have been associated with dramatic platelet count drops during cardiopulmonary bypass (CPB). It has also been shown that