Zobrazeno 1 - 5
of 5
pro vyhledávání: '"Debra Echt"'
Autor:
Todd A. Thompson, Raymond B. Baggs, Takashi Miyamoto, Sergio Kobal, Charles W. Francis, Huai Luo, Yoram Neuman, Veijo Suorsa, Robert J. Siegel, Debra Echt, Valentina Suchkova, Michael J. Horzewski
Publikováno v:
Journal of the American College of Cardiology. 44:1454-1458
ObjectivesWe evaluated whether ultrasound improves myocardial tissue perfusion in 14 animals with coronary artery occlusion.BackgroundA recent study demonstrated that low-frequency ultrasound improves tissue perfusion in the rabbit ischemic limb, but
Autor:
Takahiro Iwami, Yoram Neuman, Yasuhiro Honda, Sergio Kobal, James Mirocha, Michael C. Fishbein, Robert J. Siegel, Huai Luo, Fumiaki Ikeno, Debra Echt, Doo-Soo Jeon, Takashi Miyamoto, Michael J. Horzewski
Publikováno v:
Journal of the American College of Cardiology. 41(9):1623-1627
Objectives We evaluated the coronary vasodilatory effects of transcutaneous low-frequency (27-kHz) ultrasound (USD). Background Ultrasound has been shown to affect vascular function. Methods Ultrasound energy was administered transcutaneously to 12 d
Autor:
Michael, Hudson, Adam, Greenbaum, Laura, Brenton, C Michael, Gibson, Robert, Siegel, Lisa R, Reeves, Miguel Fiol, Sala, George, McKendall, Jorge, Bluguermann, Debra, Echt, E Magnus, Ohman, W Douglas, Weaver
Publikováno v:
JACC. Cardiovascular interventions. 3(3)
We investigated whether transcutaneous ultrasound (TUS) augments coronary thrombolysis and achieves higher rates of Thrombolysis In Myocardial Infarction (TIMI) flow grade 3 and ST-segment resolution in patients with ST-segment elevation myocardial i
Autor:
Takashi, Miyamoto, Yoram, Neuman, Huai, Luo, Doo-Soo, Jeon, Sergio, Kobal, Fumiaki, Ikeno, Michael, Horzewski, Yasuhiro, Honda, James M, Mirocha, Takahiro, Iwami, Debra, Echt, Michael C, Fishbein, Robert J, Siegel
Publikováno v:
Journal of the American College of Cardiology. 41(9)
We evaluated the coronary vasodilatory effects of transcutaneous low-frequency (27-kHz) ultrasound (USD).Ultrasound has been shown to affect vascular function.Ultrasound energy was administered transcutaneously to 12 dogs. Coronary arterial dimension
Publikováno v:
Journal of Electrocardiology. 13:199-203
Summary A case of concealed bigeminy is presented in which two forms of extrasystolic complexes were evident on the ECG. One form (type B) appeared after a single conducted sinus beat, in a pattern of manifest bigeminy. The other form (type A) occurr