Zobrazeno 1 - 10
of 15
pro vyhledávání: '"David M. Hynes"'
Publikováno v:
The Lancet. 350:657-660
To many people radiology is synonymous with films. For 20 years or so, however, it has been possible to capture digitally data traditionally displayed on film, and that was true from the beginning of computed tomography and magnetic resonance imaging
Publikováno v:
SPIE Proceedings.
Digital Video Fluorography (DVF) has been developed over the past fifteen years. Although much emphasis has been placed upon digital subtraction angiography (DSA) the concept has been extended to gfluoroscopic examinations. Indeed, 1024 x 1024 DVF sy
Publikováno v:
SPIE Proceedings.
Teleradiology has been discussed for many years yet its use to thte has been limited. An important factor is the need for adequate image quality so that a diagnosis can be made with confidence. We have developed several generations of digital fluoros
Publikováno v:
Radiology. 133:751-755
A feasibility study for the photographic recording of fluoroscopic images from a high resolution system is described. Resolution on the television monitor was 2 line pairs/mm, making clinically acceptable recordings possible. Significant reductions i
Publikováno v:
Radiology. 155:519-523
The combination of videofluorography and pulsed fluoroscopy using an analog videodisc system has previously been investigated with regard to image quality and potential for dose reduction. The authors found that the system could be improved still fur
Publikováno v:
Radiology. 136:213-218
The image quality of photofluorographic spot films (70, 100 or 105mm) has bee gradually improving as high resolution image intensification has evolved. With newly available 1023-line fluoroscopic monitors providing 2.8 line pairs/mm resolution, it is
Publikováno v:
Radiology. 145:505-509
Autor:
Ronald G. Grainger, David M. Hynes
Publikováno v:
Clinical Radiology. 19:438-456
The angiographic techniques employed and the anatomical deformities demonstrated are reported in seventy-eight patients with coarctation of aorta and similar abnormalities. The conventional type of coarctation was found in forty-one patients but six
Publikováno v:
Application of Optical Instrumentation in Medicine VIII.
A total low dose fluoroscopy system has been developed,using a Siemens Videomed H 1023 line 25MHz television system, and a modified Matrix Videoimager, multi-image camera for recording spot films. The radiation dose during fluoroscopy has been reduce
Publikováno v:
Application of Optical Instrumentation in Medicine VII.
The image quality available on photofluorographic spot films (70,100 or 105 mm) has been gradually improving as high resolution image intensification has evolved. This paper describes that a resolution of 2.5 to 3 line pairs is now available on the S