Zobrazeno 1 - 10
of 31
pro vyhledávání: '"David F, Wax"'
Publikováno v:
Catheterization and Cardiovascular Interventions. 93:1382-1384
A 60-year-old woman with progressive dyspnea and cyanosis, O2-dependent pulmonary hypertension despite optimal medical therapy and remote atrial septostomy presented with worsening cyanosis and right-to-left shunting. The creation of a "fenestrated"
Publikováno v:
Pediatric Cardiology. 38:308-313
Endomyocardial biopsy (EMB) with fluoroscopy is used for rejection surveillance in pediatric heart transplantation. Lowering frame rate may reduce radiation, but decreases temporal resolution and image quality. We undertook a quality initiative reduc
Publikováno v:
World Journal for Pediatric and Congenital Heart Surgery. 11:NP44-NP46
Although minimally invasive repair of pectus excavatum has been shown to have a low complication rate in large series, several case reports have documented life-threatening complications, including bleeding and cardiac perforation. We present a rare
Autor:
Jaxk Reeves, David F. Wax, David G. Nykanen, Daisuke Kobayashi, Thomas J. Forbes, Yan Du, Wei Du, Nathaniel W. Taggart, Allison K. Cabalka
Publikováno v:
The American journal of cardiology. 123(9)
The purpose of this study was to define the risk for adults with congenital heart disease who underwent cardiac catheterization and to propose a precatheterization risk scoring system. Data were prospectively collected using a multicenter registry of
Publikováno v:
World Journal for Pediatric and Congenital Heart Surgery. 7:223-226
We report a case of a 15-month-old female presenting with a large aortopulmonary window during a medical mission. The optimal surgical correction for this patient would be based on an estimation of her pulmonary vascular reactivity. This report detai
Autor:
David F. Wax, Jeffrey G. Gossett, Amy S. Lay, Laura Mansfield, Jennifer M. Acevedo, Karen Rychlik
Publikováno v:
Catheterization and Cardiovascular Interventions. 86:1041-1047
Background Trans-catheter closure of atrial septal defects (ASD) with the Amplatzer Septal Occluder (ASO) device is safe and effective, but concern over erosions has increased. Devices are placed in growing children but septal growth after ASOs is il
Autor:
Daisuke Kobayashi, Alexander J. Javois, Jeffery Meadows, Abhay Divekar, Wei Du, Thomas J. Forbes, Daniel H. Gruenstein, Phillip Moore, David F. Wax, Joseph N. Graziano, Walter Mosquera Alvarez, Carlos A. C. Pedra, James Hill, Thomas E. Fagan, David Nykanen
Publikováno v:
Catheterization and Cardiovascular Interventions. 84:785-793
OBJECTIVES We examine normalized air Kerma area product (PKA ) by body weight (PKA /BW) as a reference value of radiation dose and benchmark PKA /BW in pediatric laboratories using a multicenter registry database. BACKGROUND Reduction of radiation do
Autor:
Sunjay Kaushal, David F. Wax, Shivani Patel, Guy Randolph, Carl L. Backer, Jay N. Patel, Constantine D. Mavroudis, Thomas J. Weigel, Brandon L. Walker
Publikováno v:
The Annals of Thoracic Surgery. 88:1932-1938
Background We began using the technique of resection with extended end-to-end anastomosis for infants and children with coarctation of the aorta in 1991. The purpose of this review is to evaluate the midterm outcomes of this technique, specifically d
Autor:
Melissa A. Jennings, David F. Wax, Charles J. Coté, Kimberly Kurczak‐Klippstein, Carla L. Gorski
Publikováno v:
Pediatric Anesthesia. 17:661-666
This prospective observational study compared endtidal carbon dioxide (P(E)CO(2)) with blood gas carbon dioxide (PaCO(2)) values in children sedated by nonanesthesiologists for cardiac catheterization.A nasal cannula designed to obtain gas sampling s
Autor:
David F. Wax, Evan M. Zahn, David G. Nykanen, Satinder Sandhu, Daniel R. Turner, William E. Hellenbrand, Troy A. Johnston, Wei Du, Swati Garekar, Liwen Tang, David F. Teitel, Thomas J. Forbes, Ziyad M. Hijazi, John P. Cheatham, Shakeel A. Qureshi, Carlos A. C. Pedra, Zahid Amin, Thomas E. Fagan, Horst Sievert, Alejandro Torres, Donald J. Hagler, Makram R. Ebeid, John F. Rhodes, Jeremy Ringwald, Phillip M. Moore, Thomas K. Jones, Robert H. Pass
Publikováno v:
Catheterization and Cardiovascular Interventions. 70:569-577
Background: We report a multiinstitutional study on intermediate-term outcome of intravascular stenting for treatment of coarctation of the aorta using integrated arch imaging (IAI) techniques. Methods and Results: Medical records of 578 patients fro