Zobrazeno 1 - 10
of 20
pro vyhledávání: '"Daoud R. Iskander"'
Publikováno v:
IEEE Transactions on Biomedical Engineering. 56:1473-1481
A new method for noninvasive assessment of tear film surface quality (TFSQ) is proposed. The method is based on high-speed videokeratoscopy in which the corneal area for the analysis is dynamically estimated in a manner that removes videokeratoscopy
Publikováno v:
IEEE Transactions on Biomedical Engineering. 56:493-499
High-speed videokeratoscopy is an emerging technique that enables study of the corneal surface and tear-film dynamics. Unlike its static predecessor, this new technique results in a very large amount of digital data for which storage needs become sig
Publikováno v:
IEEE Transactions on Biomedical Engineering. 55:2381-2387
Videokeratoscopy techniques rely on a number of factors in order to achieve accurate estimates of corneal surface topography. Good tear film quality, minimal reflections from eyelashes, and minimal eye movements are essential for corneal topography e
Publikováno v:
Eye. 21:624-632
PURPOSE: To investigate fluctuations in the ocular surface, we used high-speed videokeratoscopy (50 Hz) to measure the dynamics of the ocular surface topography. METHODS: Ocular surface height difference maps were computed to illustrate the changes i
Publikováno v:
IEEE Transactions on Biomedical Engineering
High-speed videokeratoscopy (HSV) is an emerging technology that has the potential to acquire information on the dynamics of corneal topography and tear-film behavior. We show that the surface regularity and asymmetry indices, which are traditionally
Publikováno v:
IEEE Transactions on Biomedical Engineering. 51:1969-1980
The optics of the human eye are not static in steady viewing conditions and exhibit microfluctuations. Previous methods used for analyzing dynamic changes in the eye's optics include simple Fourier-transform-based methods, which have been used in stu
Autor:
Daoud R. Iskander, Mark R. Morelande
Publikováno v:
IEEE Transactions on Signal Processing. 51:3043-3052
Two detectors of symmetrically distributed independent timing jitter in a data record composed of a complex harmonic in additive white Gaussian noise are proposed. The proposed detectors are computationally efficient, and although they are formulated
Publikováno v:
2009 IEEE/SP 15th Workshop on Statistical Signal Processing.
Modelling of interferometric signals related to tear film surface quality is considered. In the context of tear film surface quality estimation in normal healthy eyes, two clinical parameters are of interest: the build-up time, and the average interb
Publikováno v:
IEEE transactions on bio-medical engineering. 56(3)
Corneal topography estimation that is based on the Placido disk principle relies on good quality of precorneal tear film and sufficiently wide eyelid (palpebral) aperture to avoid reflections from eyelashes. However, in practice, these conditions are
Publikováno v:
MMSP
An optimal videokeratoscopic image presents a strong well-oriented pattern over the majority of the measured corneal surface. In the presence of interference, arising from reflections from eyelashes or tear film instability, the patternpsilas flow is