Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Danrui Ma"'
Publikováno v:
High Voltage, Vol 6, Iss 6, Pp 986-996 (2021)
Abstract Inspection of partial discharge before contamination flashover is of great importance for preventing exterior insulation accidents. In this study, a new method for identification of discharge severities is proposed. Specifically, a low‐cos
Externí odkaz:
https://doaj.org/article/27b7f0a49c374c73936eda6f7a68d18d
Publikováno v:
Symmetry, Vol 12, Iss 11, p 1780 (2020)
Control of the maglev system is one of the most significant technologies of the maglev train. The common proportion integration differentiation (PID) method, which has fixed control parameters, ignores the non-linearity and uncertainty of the model i
Externí odkaz:
https://doaj.org/article/b8595abcfd964ecc856fd9f0007fccfc
Publikováno v:
High Voltage, Vol 6, Iss 6, Pp 986-996 (2021)
Inspection of partial discharge before contamination flashover is of great importance for preventing exterior insulation accidents. In this study, a new method for identification of discharge severities is proposed. Specifically, a low‐cost ultravi
Publikováno v:
2022 IEEE 5th International Electrical and Energy Conference (CIEEC).
Publikováno v:
2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO).
Publikováno v:
2020 Chinese Automation Congress (CAC).
As a new type of rail transit, maglev traffic has shown a rapid development momentum. This paper designs a scheme that integrates the functions of position, speed and height measurement for maglev train. The principle of improving accuracy of the sch
Publikováno v:
Symmetry, Vol 12, Iss 1780, p 1780 (2020)
Symmetry
Volume 12
Issue 11
Symmetry
Volume 12
Issue 11
Control of the maglev system is one of the most significant technologies of the maglev train. The common proportion integration differentiation (PID) method, which has fixed control parameters, ignores the non-linearity and uncertainty of the model i
Publikováno v:
2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE).
Partial discharge detection before insulator flashover plays a significant role in external insulation fault diagnosis. Ultraviolet (UV) detection has the advantages of non-contact measurement and high cost performance. This paper studies the relatio
Publikováno v:
2019 Chinese Automation Congress (CAC).
Maglev train is a modern rail vehicle with low energy consumption, low noise and high comfort. Due to the monitoring of the running state of the train during the operation and commissioning of the maglev train, there are some problems, such as large
Publikováno v:
2018 28th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV).
With the gradual deterioration of atmospheric environment, pollution accumulation causes the increase in flashover accidents, which seriously threatens the safety and stability of power system. The detection of partial discharge for insulators is an