Zobrazeno 1 - 5
of 5
pro vyhledávání: '"Daniela Ristanić"'
Autor:
Borislav Hinkov, Florian Pilat, Laurin Lux, Patricia L. Souza, Mauro David, Andreas Schwaighofer, Daniela Ristanić, Benedikt Schwarz, Hermann Detz, Aaron M. Andrews, Bernhard Lendl, Gottfried Strasser
Publikováno v:
Nature Communications, Vol 13, Iss 1, Pp 1-10 (2022)
Rapid investigation of chemical reactions is a challenge in bio-medical analysis. Here, the authors demonstrate sensitive in-situ real-time reaction-monitoring of conformational changes in protein solution, based on a fingertip-sized mid-IR lab-on-a-
Externí odkaz:
https://doaj.org/article/9f587fd10cb44a5991d7408888e3bda0
Autor:
Florian Pilat, Benedikt Schwarz, Bettina Baumgartner, Daniela Ristanić, Hermann Detz, Aaron M. Andrews, Bernhard Lendl, Gottfried Strasser, Borislav Hinkov
Publikováno v:
Lab on a Chip. 23:1816-1824
A sensitive and selective monolithic mid-IR lab-on-a-chip for real-time analysis of water-residuals in solvents with comparable LOD to Karl–Fischer titration.
Autor:
Borislav Hinkov, Florian Pilat, Mauro David, Georg Marschick, Elena Arigliani, Patricia L. Souza, Andreas Schwaighofer, Laurin Lux, Bettina Baumgartner, Daniela Ristanić, Benedikt Schwarz, Hermann Detz, Aaron M. Andrews, Bernhard Lendl, Gottfried Strasser
Publikováno v:
Conference on Lasers and Electro-Optics.
We present a fingertip-sized mid-IR lab-on-a-chip for selective and sensitive time-resolved spectroscopy of liquids. Breakthrough beyond state-of-the-art operation of our monolithic sensor is demonstrated by real-time in-situ reaction-monitoring of c
Autor:
Borislav Hinkov, Florian Pilat, Laurin Lux, Patricia L. Souza, Mauro David, Andreas Schwaighofer, Bettina Baumgartner, Daniela Ristanić, Benedikt Schwarz, Hermann Detz, Aaron M. Andrews, Bernhard Lendl, Gottfried Strasser
Publikováno v:
Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES).
We present a monolithic mid-infrared lab-on-a-chip for sensitive and selective real-time liquid spectroscopy. Beyond state-of-the-art operation of our fingertip-sized devices is demonstrated by in-situ reaction-monitoring of thermally-induced protein
Monolithically integrated mid-infrared lab-on-a-chip using plasmonics and quantum cascade structures
Autor:
Benedikt, Schwarz, Peter, Reininger, Daniela, Ristanić, Hermann, Detz, Aaron Maxwell, Andrews, Werner, Schrenk, Gottfried, Strasser
Publikováno v:
Nature Communications
The increasing demand of rapid sensing and diagnosis in remote areas requires the development of compact and cost-effective mid-infrared sensing devices. So far, all miniaturization concepts have been demonstrated with discrete optical components. He