Daniel S. Hill, A. Nadeem Baqai
Publikováno v:
Trauma Case Reports, Vol 9, Iss , Pp 45-48 (2017)
The disadvantages of the one-third-tubular plate construct to stabilize lateral malleolar fractures include; difficulty achieving adequate cancellous screw thread purchase in the bone of the distal fragment, with subsequent risk of the screws backing
Externí odkaz:
https://doaj.org/article/9cef1ec332f54c08b5f96ceaa459f08e
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 29:1105-1113
Our aim was to question the usefulness of a three-phase bone scan in the evaluation of pain in the knee region after TKR. Our hypothesis was that an abnormal investigation had a poor association with the presence of infection or loosening, and did no
Autor:
Daniel S. Hill, Hans Marynissen
Publikováno v:
Spine. 43:E1210-E1217
STUDY DESIGN A retrospective cross-sectional analysis. OBJECTIVE The aim of this study was to describe the provision of a spinal service using an electronic platform to direct management from an external spinal unit, and to quantify the time taken to
Autor:
A. Nadeem Baqai, Daniel S. Hill
Publikováno v:
Trauma Case Reports, Vol 9, Iss, Pp 45-48 (2017)
Trauma Case Reports
Trauma Case Reports
The disadvantages of the one-third-tubular plate construct to stabilize lateral malleolar fractures include; difficulty achieving adequate cancellous screw thread purchase in the bone of the distal fragment, with subsequent risk of the screws backing
Publikováno v:
HIP International. 28:96-100
Introduction: Surgical intervention for patients presenting with a fractured neck of femur is common, however the best method of skin closure remains unclear. It has been suggested that the use of metallic skin clips in the closure of hip wounds may
Publikováno v:
HIP International. 26:e52-e55
Background Highly cross-linked polyethylene in total hip arthroplasty (THA) has been shown to decrease wear rate compared with a conventional polyethylene liner. However, it has also been reported that the manufacturing processes can cause early fail
Publikováno v:
Hip international : the journal of clinical and experimental research on hip pathology and therapy. 28(3)
Introduction:The aim of this study was to assess the benefit of a Technetium-99M (HDP) 3-phase bone scan (TPBS) as an additional diagnostic test in the evaluation of pain in the hip region following cemented total hip replacement (THR) surgery.Method
Publikováno v:
European journal of orthopaedic surgerytraumatology : orthopedie traumatologie. 28(5)
The aim of this survey was to explore knee surgeons’ opinions and practices regarding the management of symptomatic knee osteoarthritis in obesity. Questionnaires were sent electronically to all consultant members of the British Association for Sur
Publikováno v:
European Journal of Orthopaedic Surgery & Traumatology. 28:975-975
The corresponding author would like to state a different e-mail address: drdanielhill@icloud.com.
Autor:
Daniel S Hill, Richard Parry, Robert G. Taylor, Leigh Cowling, Fleur Jackson, Jonathan P. Wyatt
Publikováno v:
Emergency Medicine Journal. 30:68-69
Email has transformed communication in the National Health Service. Handling a torrent of unfocused communication is a potential burden on the clinician's time and a source of stress at work. A prospective study of the number of emails, links and att