Zobrazeno 1 - 10
of 38
pro vyhledávání: '"Daniel Kolditz"'
Autor:
Sojin, Shim, Daniel, Kolditz, Christian, Steiding, Veikko, Ruth, Andreas M, Hoetker, Jan, Unkelbach, Andreas, Boss
Publikováno v:
Medical Physics. 50:2417-2428
Spiral breast computed tomography (BCT) equipped with a photon-counting detector is a new radiological modality allowing for the compression-free acquisition of high-resolution 3-D datasets of the breast. Optimized dose exposu04170/re setups accordin
Publikováno v:
Investigative Radiology. 52:349-359
The performance of metal artifact reduction (MAR) methods in x-ray computed tomography (CT) suffers from incorrect identification of metallic implants in the artifact-affected volumetric images. The aim of this study was to investigate potential impr
Autor:
Barbara Brehm, Willi A. Kalender, Christian Steiding, Matthias Hammon, Evelyn Wenkel, Daniel Kolditz, Ann-Christin Rößler, Veikko Ruth, Rüdiger Schulz-Wendtland, Caroline Preuss, Sandra Christina Peter
Publikováno v:
Academic Radiology. 24:184-190
Rationale and Objectives This study compared a novel photon-counting breast computed tomography (pcBCT) system with digital mammography (DM) and digital breast tomosynthesis (DBT) systems. For this reason, surgical specimens were examined with all th
Publikováno v:
Investigative Radiology. 52:81-86
Recent studies have shown a substantial reduction of radiation dose from computed tomography (CT) scans down to 0.1 mSv for lung cancer screening and cardiac examinations, when applying optimization techniques. Hence, CT localizer radiographs (LRs) m
Publikováno v:
Medical physicsReferences. 47(7)
Purpose Contrast-enhanced imaging of the breast is frequently used in breast MRI and has recently become more common in mammography. The purpose of this study was to make single-scan contrast-enhanced imaging feasible for photon-counting breast CT (p
Autor:
Willi A. Kalender, Evelyn Wenkel, Ann-Christin Rößler, Ferdinand Lück, Veikko Ruth, Christian Steiding, Daniel Kolditz
Publikováno v:
European Radiology. 27:1081-1086
X-ray computed tomography (CT) has been proposed and evaluated multiple times as a potentially alternative method for breast imaging. All efforts shown so far have been criticized and partly disapproved because of their limited spatial resolution and
Autor:
Hubertus Pietsch, Ann-Christin Roessler, Martin Hupfer, Willi A. Kalender, Gregor Jost, Daniel Kolditz
Publikováno v:
Investigative Radiology. 51:249-254
Objectives Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for fur
Autor:
Martin Hupfer, Jan D. Kuttig, Daniel Kolditz, Christian Steiding, Willi A. Kalender, Marek Karolczak
Publikováno v:
Physica Medica. 31:406-413
Purpose To investigate the dose saving potential of direct-converting CdTe photon-counting detector technology for dedicated breast CT. Materials and methods We analyzed the modulation transfer function (MTF), the noise power spectrum (NPS) and the d
Autor:
Marcel Beister, Daniel Kolditz, Martin Hupfer, Natalia Saltybaeva, Willi A. Kalender, Bernhard Schmidt
Publikováno v:
Physica Medica. 30:925-933
The estimation of patient dose using Monte Carlo (MC) simulations based on the available patient CT images is limited to the length of the scan. Software tools for dose estimation based on standard computational phantoms overcome this problem; howeve
Publikováno v:
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 187:283-290
Purpose: The aim of this work was to implement, validate, and compare two procedures for routine image quality (IQ) assurance in dental cone-beam computed tomography (CBCT): 1. the German standard DIN 6868 – 161 introduced in 2013 and 2. the establ