Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Danièle S. Aron-Rosa"'
Publikováno v:
Journal of Refractive Surgery. 10:575-581
BACKGROUND: We designed an excimer laser keratomileusis delivery system to increase the regularity of the refractive cut surface and allow greater precision in the level and shape of the ablated zone. METHODS: A parallel faced corneal disc was produc
Autor:
Danièle S Aron Rosa
Publikováno v:
Journal of Refractive Surgery. 17
PURPOSE: To report unexpected outcomes in three patients after uneventful laser in situ keratomileusis (LASEK) performed using the Nidek EC-5000 excimer laser and the Hansatome microkeratome (Bausch & Lomb Surgical). METHODS: LASIK was performed with
Publikováno v:
Journal of cataract and refractive surgery. 26(5)
A challenge of the sutured posterior chamber intraocular lens (iol) technique is to perform blind actions behind the iris. to avoid imprecise transscleral sutures and complications, we use an endoscopic procedure with 2 goals to control the entry sit
Publikováno v:
Journal of cataract and refractive surgery. 25(7)
Purpose To evaluate the efficacy, predictability, and safety of excimer laser photoastigmatic refractive keratectomy (PARK) to correct compound myopic astigmatism. Setting Departments of Ophthalmology, Robert Debre Hospital and Rothschild Foundation,
Publikováno v:
Journal of Cataract and Refractive Surgery. 16:257-259
An efficient, simple technique for one-movement insertion of the superior intraocular lens loop into the capsular bag is described. This bimanual technique avoids undue stress on the capsular bag and zonules, may be used with all extracapsular techni
Autor:
Nicole Burin, Ricardo Valdes, Coletter Gallinaro, Jean Luc Febraro, Joseph Colin, Béatrice Cochener, B. Aron, S. Ganem, Danièle S. Aron-Rosa
Publikováno v:
Journal of cataract and refractive surgery. 21(6)
Efficacy, predictability, and safety of excimer laser photorefractive keratectomy were evaluated at centers in Paris and Brest, France. Photoablation was performed with the VISX laser on 265 eyes (151 at the Paris center and 114 at the Brest center).
Publikováno v:
Journal of cataract and refractive surgery. 18(6)
One hundred twenty-two patients, who were followed for ten years, had bilateral extracapsular cataract surgery with implantation of J-looped posterior chamber lenses between 1980 and 1981. On the first eye an anterior capsulotomy was performed with a
Publikováno v:
Journal of cataract and refractive surgery. 16(5)
There is an increasing interest in the use of the-excimer laser in ophthalmology, particularly in refractive surgery. The argon fluoride (193 nm) excimer laser ablates tissue with a high degree of precision and without any mechanical or thermal damag
Publikováno v:
Laser Safety, Eyesafe Laser Systems, and Laser Eye Protection.
Excimer laser linear excisions are performed on both rabbit and human cadaver corneas by varying the excision direction and the laser pulse number. The shape , width and depth of the excisions as a function of these parameters are studied. Excisions
Autor:
Patricia E. Bath, Lawrence D. True, Danièle S. Aron-Rosa, Carol F. Boerner, Francoise Carre, Michel Gross, Jean Claude Timsit, Thierry J. Hufnagel
Publikováno v:
American Journal of Ophthalmology. 103:454-464
A pulsed excimer argon-fluorine laser was used to produce corneal incisions in vivo in a human cornea. Fourteen days after the laser surgery, the incisions were examined by light and transmission electron microscopy. There was good initial healing, w