Publikováno v:
Energies, Vol 17, Iss 10, p 2274 (2024)
Although XLPE cables are widely used in power transmission and distribution systems, their insulating properties are susceptible to degradation due to thermal aging. In order to clarify the influence law of the thermal aging process on the structural
Externí odkaz:
https://doaj.org/article/d77d6cf178f641f2965cdb8f37ed23ab
Publikováno v:
Springer Proceedings in Physics ISBN: 9789819915750
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2ad66aac333c4492c8e8a519112897ff
https://doi.org/10.1007/978-981-99-1576-7_10
https://doi.org/10.1007/978-981-99-1576-7_10
Publikováno v:
2022 IEEE Conference on Telecommunications, Optics and Computer Science (TOCS).
Comparative analysis of the impact of multiple faults on the performance of fast repulsion mechanism
Publikováno v:
2022 IEEE 2nd International Conference on Data Science and Computer Application (ICDSCA).
Publikováno v:
2022 4th International Conference on Artificial Intelligence and Advanced Manufacturing (AIAM).
Autor:
Long Kaihua, Yang Dawei, Hao Jiang, Dangguo Xu, Qin Yifan, Wei Cai, Lingru Ning, Peng Zhaowei
Publikováno v:
2020 6th Global Electromagnetic Compatibility Conference (GEMCCON).
The main branch of 500kV high-voltage DC circuit-breaker (HVDC CB) adopts a series structure of multiple fast mechanical switches, which requires an effective distance within 2ms and can withstand over-voltage. Therefore, higher requirements on the d
Publikováno v:
2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE).
With the wide application of high-voltage direct current (HVDC), cross-linked polyethylene (XLPE) cable may have some defects in production and operation. In the construction site, the method of using AC test voltage to detect the local defects of DC
Publikováno v:
2020 IEEE Electrical Insulation Conference (EIC).
The diagnosis of XLPE cable lines by partial discharge (PD) has always been a key technical issue. As an important parameter reflecting the insulation status of XLPE cable equipment, partial discharge is closely related to its insulation status. A st
Publikováno v:
2012 IEEE International Conference on Condition Monitoring and Diagnosis.
Gas insulated substation (GIS) has been widely used in the field of high voltage power transmission. However, GIS equipments are witnessing more and more internal faults and failures as the voltage class of power network and capacity of power system
Publikováno v:
2010 IEEE International Symposium on Electrical Insulation.
The widespread application of SF6 gas insulated substations (GIS) in high voltage power transmission requires reliable fault detection and diagnosis techniques. Partial discharge (PD) detection has so far been proven to be the most effective tool for