Zobrazeno 1 - 10
of 70
pro vyhledávání: '"Dan-Feng Lu"'
Autor:
Jie Jia, Yu Zhao, Ji-Qun Yang, Dan-Feng Lu, Xiu-Ling Zhang, Jun-Hong Mao, Kun-Hua Wang, Jian-Hua Wang, Yi-Qun Kuang
Publikováno v:
iScience, Vol 25, Iss 12, Pp 105559- (2022)
Summary: Incomplete immune reconstitution happens in some HIV-infected patients who have achieved persistent viral suppression under antiretroviral therapy (ART). We performed single-cell RNA sequencing for peripheral blood mononuclear cells to analy
Externí odkaz:
https://doaj.org/article/ded5d3ec34114ceca19fc7778c779a92
Autor:
Fu Li, Bao-Wen Du, Dan-Feng Lu, Wen-Xuan Wu, Kanjana Wongkrajang, Lun Wang, Wen-Chen Pu, Chang-Lu Liu, Han-Wei Liu, Ming-Kui Wang, Fei Wang
Publikováno v:
Scientific Reports, Vol 7, Iss 1, Pp 1-12 (2017)
Abstract Epimedium brevicornum Maxim has a long history of use in the treatment of estrogen deficiency-related diseases. However, the chemical constituents and mechanism of action of this medicinal plant are not fully understood. In the present study
Externí odkaz:
https://doaj.org/article/cdbf79c242b5456e9d71bb62e04b9411
Publikováno v:
Sensors, Vol 17, Iss 6, p 1255 (2017)
A wavelength-interrogated surface plasmon resonance (SPR) sensor based on a nanoporous gold (NPG) film has been fabricated for the sensitive detection of trace quantities of benzo[a]pyrene (BaP) in water. The large-area uniform NPG film was prepared
Externí odkaz:
https://doaj.org/article/252d2c3316584d16a1fe6cd8a53f4d95
Publikováno v:
Journal of Lightwave Technology. 37:2694-2699
A compact low-temperature crosstalk all-fiber ultrasonic sensor based on quadrature point phase step is proposed and experimentally demonstrated for the detection of high-intensity focused ultrasound (HIFU). The end facet of the graded index fiber wa
Publikováno v:
ACS Photonics. 5:1273-1280
Polycyclic aromatic hydrocarbons (PAHs) are always regarded as contaminants originating from the incomplete combustion of organic compounds. Benzo[a]pyrene (B[a]P) can be adopted as a marker for the overall PAH mixture due to its ultratoxic property,
Publikováno v:
IEEE Sensors Journal. 17:8332-8337
A compact all-fibre vibration sensor based on power leakage at resonance wavelengths of a tapered capillary fiber is proposed and experimentally demonstrated. A section of the capillary fiber was selectively etched by using hydrofluoricacid, which fo
Publikováno v:
The Journal of Physical Chemistry C. 121:19173-19181
A metal-clad optical waveguide sensor based on guided-mode resonance spectroscopy has been developed using a mesoporous TiO2 film as the chemical-sensitive core layer. The sol–gel block copolymer templated mesoporous TiO2 films are ∼275 nm thick,
Publikováno v:
IEEE Photonics Technology Letters. 29:857-860
A high-sensitive strain sensor based on the anti-resonant reflecting optical waveguide in a double-layered Fabry–Perot resonator is proposed and experimentally demonstrated. A section of the silica hollow core fiber with a small diameter was insert
Publikováno v:
IEEE Journal of Selected Topics in Quantum Electronics. 23:193-198
A capillary covered silica hollow core fiber (HCF) has been designed and tested for the measurement of displacement based on antiresonant reflecting optical waveguide. A section of the silica HCF was inserted into a silver coated capillary. A Fabry
Autor:
sup> 国民核生化灾害防护国家重点实验室,北京 ,, Dan-Feng Lu, sup> 中国科学院电子学研究所,传感技术联合国家重点实验室,北京 ,, Xiao-Qing Gong, 中国科学院大学,北京, Zhi-Bo Fan, Ran Gao, QI Zhi-Mei
Publikováno v:
Acta Physico-Chimica Sinica. 33:1001-1009