Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Damiaan F. Habets"'
Autor:
Damiaan F. Habets, Payam B. Bijari, Edward G. Lakatta, Diego Gallo, Yuanyuan Joyce Xie, Bruce A. Wasserman, Umberto Morbiducci, David A. Steinman, Ye Qiao, Maryam Etesami
Publikováno v:
Journal of The Royal Society Interface. 15:20180352
Low and oscillatory wall shear stress (WSS) has long been hypothesized as a risk factor for atherosclerosis; however, evidence has been inferred primarily from model and post-mortem studies, or clinical studies of patients with already-developed plaq
Publikováno v:
Medical Physics. 36:190-200
The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensio
Autor:
Damiaan F. Habets, Donald H. Lee, David W. Holdsworth, Irene Gulka, Derek Hyde, Paul Kalapos, David M. Pelz, Allan J. Fox
Publikováno v:
Medical Physics. 34:2968-2974
Digital subtraction angiography is being supplanted by three-dimensional imaging techniques in many clinical applications, leading to extensive use of maximum intensity projection (MIP) images to depict volumetric vascular data. The MIP algorithm pro
Autor:
Simona Hodis, Yue Yu, Adel M. Malek, Quan Long, Nicolas Aristokleous, Wenyu Fu, Salvatore Cito, David F. Kallmes, Francis Loth, Amirhossein Arzani, Leonid Goubergrits, Michael Walsh, Damiaan F. Habets, Nicholas Shaffer, Hardeep S. Kalsi, Alexandra Lauric, Prahlad G. Menon, Yannis Papaharilaou, Yumnah Mohamied, Frank H. Gijsen, Liam Morris, Patrick Segers, J. A. Costelloe, Hui Meng, Jens Schaller, Ender A. Finol, Kerem Pekkan, Joris Bols, George Em Karniadakis, Kenichi Kono, Jianping Xiang, Véronique Peiffer, Philipp Berg, Joris Degroote, Shawn C. Shadden, Vitaly O. Kheyfets, Jan Vierendeels, Spencer J. Sherwin, Adrian G. Lynch, Yiemeng Hoi, Gabriel Usera, Mariana Mendina, Mahdi Esmaily Moghadam, Leonard D. Browne, David A. Steinman, Alison L. Marsden, Paul Fahy, Kengo Katagiri, Aike Qiao, Marie Oshima, Neil W. Bressloff, Gábor Janiga, Kristian Valen-Sendstad, Andreas S. Anayiotos, Merih Cibis, Jordi Pallares
Publikováno v:
Journal of biomechanical engineering. 135(2)
Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase
Autor:
Petar Seslija, Pencilla Lang, Terry M. Peters, Michael W. A. Chu, David W. Holdsworth, Damiaan F. Habets
Publikováno v:
Lecture Notes in Computer Science ISBN: 9783642156984
MIAR
MIAR
Registration and fusion of real-time trans-esophageal (TEE) and live fluoroscopy images have potential to provide improved visualization during minimally invasive aortic valve replacement and other cardiac interventions. We present an approach for ac
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::119af6507e2074b5148f90bef29383e6
https://doi.org/10.1007/978-3-642-15699-1_36
https://doi.org/10.1007/978-3-642-15699-1_36
Publikováno v:
Medical physics. 36(1)
The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensio
Publikováno v:
Medical Imaging: Image-Guided Procedures
Fluoroscopy is widely used for intra-procedure image guidance, however its planar images provide limited information about the location of the surgical tools or targets in three-dimensional space. An iterative method based on the projection-Procruste
Autor:
David A. Steinman, G. R. Stuhne, David W. Holdsworth, Stephen P. Lownie, Damiaan F. Habets, Hristo N. Nikolov, Matthew D. Ford
Publikováno v:
IEEE transactions on medical imaging. 24(12)
It has recently become possible to simulate aneurysmal blood flow dynamics in a patient-specific manner via the coupling of three-dimensional (3-D) X-ray angiography and computational fluid dynamics (CFD). Before such image-based CFD models can be us
Publikováno v:
SPIE Proceedings.
Recent advances in imaging technology have brought high-resolution imaging into the practical laboratory setting. As a result, there has been increasing interest in imaging molecular and cellular processes in live animals. To image a single cell, a c
Publikováno v:
Medical Imaging: Image-Guided Procedures
minimum stenosis measurements. Although virtually any viewing angle of the VSA was possible, the minimum stenosisgrades were not significantly higher than that of the DSAs. Our study of 38 arteries yielded a sensitivity and specificityof 100% (using