Zobrazeno 1 - 10
of 14
pro vyhledávání: '"D.L. Churakov"'
Autor:
V.P. Tchernyshev, L.N. Gusev, M.M. Smolin, S.A. Simonychev, V.M. Shershukov, G. Smirnov, W. Turchinetz, V.S. Sopov, T.A. Osipova, D.L. Churakov, S.G. Belogurov, V.H. Dodohov, R.A. Minakova, I.A. Rogovsky, A.D. Brastilov, D.Y. Akimov, V.F. Kuzichev, Mingshui Chen, V.N. Lebedenko, A. A. Burenkov, V.N. Afonasyev, G. Safronov, A. Bolozdynya, V.N. Solovov
Publikováno v:
IEEE Transactions on Nuclear Science. 42:2244-2249
A scintillating LXe/LKr electromagnetic calorimeter has been built at the ITEP and tested at the BATES (MIT) accelerator. The detector consists of PMT matrix and 45 light collecting cells made of aluminized 50 microns Mylar partially covered with p-t
Autor:
V.S. Sopov, T.A. Osipova, A. A. Burenkov, D.L. Churakov, A. Bolozdynya, Mingshui Chen, V.A. Lamkov, V.P. Tchernyshev, D. Akimov
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 333:618-621
Using a combination of aluminized Mylar reflectors, with strips of wavelength shifter evaporation and photo detector insensitive to UV-light, the longitudinal uniformity of ±8% is achieved for liquid Kr and Xe scintillators in pyromidal Mylar reflec
Autor:
Konstanty Sumorok, Mingshui Chen, X. Zhang, M. Akopyan, V.F. Kuzichev, M. Werlen, G. Safronov, G. Smirnov, A. Koutchenkov, V. Vinogradov, M. Smolin, V. Sheinkman, D. Steele, Barry Blumenfeld, C. Joseph, D. Luckey, S. Belogurov, V.N. Lebedenko, A. G. Kovalenko, Y. Giomataris, Georges Charpak, A. Gougas, A. Bolozdynya, D.L. Churakov
We describe the experimental results of a new type of electron tracker, called Hadron Blind Detector or HBD. An HBD prototype was tested with gas mixtures of CF4 with He or Ne and a parallel plate avalanche chamber having a CsI photocathode of eight
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::62f84ffd6129c4c93d4fb9445d32c16c
http://cds.cern.ch/record/255275
http://cds.cern.ch/record/255275
Autor:
G. Smirnov, A.A. Sadovsky, A. Bolozdynya, G. Safronov, D.Yu. Akimov, V.A. Lamkov, D.L. Churakov
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 332:575-576
The influence of 1.7–5.3% Xe doping on LKr scintillation decay times is observed. The decay times of τ1 = 8.7±0.6 ns, gt2 = 29±
Autor:
A. Bolozdynya, V. Egorov, S. Belogurov, V.N. Solovov, D.L. Churakov, V. L. Morgunov, S. Medved, A. Koutchenkov, G. Safronov, G. Smirnov
Publikováno v:
INSPIRE-HEP
CIÊNCIAVITAE
Scopus-Elsevier
CIÊNCIAVITAE
Scopus-Elsevier
The first results of testing a high pressure gas scintillation drift chamber as with single photomultiplier and with matrix of 7 photomultipliers placed inside of pressurized xenon are presented. Two types of ordinary glass tube photo-multipliers tha
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f4256714d43e8d7cc11810b61a89fc23
http://inspirehep.net/record/1484579
http://inspirehep.net/record/1484579
Autor:
Alexander Bolozdynya, T.A. Osipova, D.Y. Akimov, O. Petshina, A. A. Burenkov, G. Smirnov, D.L. Churakov, G. Safronov, V. N. Solovov
Publikováno v:
CIÊNCIAVITAE
Scopus-Elsevier
Scopus-Elsevier
The shape of scintillation signals, exited in liquid krypton, liquid xenon and their liquid mixture of Kr+1.7%Xe by relativistic positrons, positive pions, protons and deuterons with moments of 0.35-2.1 GeV/c is measured at a secondary beam of the IT
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e473b13a29a909b2e6cc3850a7c8aec7
http://www.scopus.com/inward/record.url?eid=2-s2.0-0030360923&partnerID=MN8TOARS
http://www.scopus.com/inward/record.url?eid=2-s2.0-0030360923&partnerID=MN8TOARS
Autor:
Mingshui Chen, I.A. Rogovsky, D.L. Churakov, V.Yu. Chepel, V.V. Sushkov, A. Koutchenkov, V.N. Lebendenko, D.Yu. Akimov, V.F. Kuzichev, A. Bolozdynya
Publikováno v:
Scopus-Elsevier
CIÊNCIAVITAE
CIÊNCIAVITAE
Liquid and solid krypton have been studied as scintillators. Attenuation length for Kr scintillation light was determined to be about 1m, after the Kr was purified by a hot Ca-getter and by a Ti discharge purifier in liquid phase. Two detectors (75 a
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::287519c31227e964eb514be6ccd5367e
http://www.scopus.com/inward/record.url?eid=2-s2.0-0027560614&partnerID=MN8TOARS
http://www.scopus.com/inward/record.url?eid=2-s2.0-0027560614&partnerID=MN8TOARS
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.