Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 15:1535-1543
Partial discharge (PD) characteristics in air, argon and helium at pressures between 101 kPa (760 Torr) to about 0.27 kPa (2 Torr) under 60 Hz AC energization were studied with various electrode arrangements. Measurements are presented for two repres
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 12:362-373
Partial discharge (PD) characteristics in air and argon under low pressures down to 13.3 Pa (0,1 Torr) and 60 Hz AC energization are studied in an energized needle-plane electrode arrangement. The electrode configuration, vacuum chamber, facilities,
Publikováno v:
2014 IEEE International Power Modulator and High Voltage Conference (IPMHVC).
The electric grid is protected from lightning damage by surge arresters. Surge arresters are sacrificial elements that must be replaced to maintain lighting protection once they are damaged. In a survey of the U.S., it has been found that the highest
Autor:
Liying Huang, D.G. Kasten
Publikováno v:
Electric Power Systems Research. 59:31-37
A mathematical model for accurately computing the ground grid and metallic structure currents in high voltage a.c. substations is presented in this paper. The developed model considers not only the current leakage to the soil but also resistive and i
Publikováno v:
IEEE Transactions on Power Delivery. 11:1454-1463
Operating a hybrid HVAC and HVDC power transmission line is an option for increasing the efficiency of power transmission and overcoming the difficulties in obtaining a new right-of-way. This paper proposes a new calculation method for the study of h
Publikováno v:
2012 IEEE International Symposium on Electrical Insulation.
About 30 percent of all overhead power distribution outages are caused by failing electrical equipment, e.g., surge arresters, cutouts, insulators, wires, and grounding. Failing equipment can be located and scheduled for removal prior to an outage. R
Publikováno v:
IEEE Transactions on Power Delivery. 9:750-756
HVDC converter station operations generate radio frequency (RF) electromagnetic (EM) noise which could interfere with adjacent communication and computer equipment, and carrier system operations. A generic Radio Frequency Computer Analysis Program (R
Publikováno v:
2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.
Publikováno v:
IEEE Transactions on Power Delivery. 8:66-72
Frequency-dependent node-to-node impedance function (NIF) models of power system equipment based on systematic broad frequency range (50 Hz to 1 MHz) external driving point impedance measurements are described. Such models are needed to calculate and
Autor:
Dennis Grosjean, Michael Rockwell, D.G. Kasten, Stephen A. Sebo, Daniel Schweickart, Titus Chen
Publikováno v:
2010 IEEE International Power Modulator and High Voltage Conference.
The flashover and breakdown characteristics of (a) electrical wiring and (b) areas between traces of printed circuit (PC) boards used in aircraft are a function of the environment in which these systems operate. As the altitude of an aircraft increas