Zobrazeno 1 - 10
of 25
pro vyhledávání: '"D.F.G. Reher"'
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 508:378-387
In the course of the past 40 years, IRMM has developed a large number of direct methods for the accurate standardisation of radionuclide solutions, all providing traceability to the SI unit. Six different measurement methods were employed to standard
Autor:
David M. Gilliam, P D'hondt, Jean Pauwels, G. Sibbens, D.F.G Reher, R. Eykens, P. Robouch, R.D. Scott
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 362:151-159
This paper describes the determination of the relative masses or relative areal densities of two new sets of reference deposits, prior to destructive analysis of subsets of these deposits by isotope dilution mass spectrometry and nondestructive analy
Autor:
T Genka, Frans Verhaegen, D Santry, M.J. Rossiter, M.J. Woods, G. Sibbens, T.T. Williams, Jan Seuntjens, Hubert Thierens, J.P. Sephton, N Drugge, H Bjerke, D.F.G. Reher, A.H.L Aalbers
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 339:386-390
At the occasion of the EUROMET Workshop on Ionising Radiation and Radioactivity at the NPL, it was decided to carry out a second intercomparison on air kerma rate (AKR) and activity measurements on 192 Ir brachytherapy sources in the frame of EUROMET
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 339:334-338
The standardization of a 50 GBq 152,154Eu extended volume source is described, as used to determine the linear power dissipation of irradiated fuel pins in materials testing reactors. This source consists of a foil of irradiated europium rolled into
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 312:47-51
The concept and realization of a computer system for the automation and data processing of results of measurements in a radionuclide metrology laboratory is described. It consists of personal computers for data acquisition connected to a VAX-3500 com
Autor:
C. Ballaux, G. Sibbens, E. De Roost, D.F.G. Reher, B. Denecke, M.J. Woods, Timotheos Altzitzoglou, E. Funck
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 312:263-268
Two 192 Ir solutions were standardized by NPL and CBNM within the framework of EUROMET project no. 219. The 4 πβ - γ -coincidence method was used for these measurements, a 4 π CsI(Tl) detector for gamma-ray spectrometry, and NaI(Tl) well counter
Autor:
B. Denecke, D.F.G. Reher
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 312:273-277
A device for the nondestructive analysis by γ-ray spectrometry of heavy waste containers is described. A method similar to the so-called segmented γ-ray scanning method is applied. The calibration of the instrument is discussed and measurements of
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 312:346-348
The current interest in the use of 192 Ir for brachytherapy prompted a re-evaluation of existing half-life values. Using the evaluation criteria adopted in a recent IAEA-Coordinated Research Programme, it was determined that the uncertainty in the ha
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.