Zobrazeno 1 - 10
of 113
pro vyhledávání: '"D. T. Burns"'
Publikováno v:
npj Science of Food, Vol 6, Iss 1, Pp 1-6 (2022)
Abstract The analytical techniques applied to verify honey authenticity are multifaceted and often result in complex data rich certificates of analysis that are open to interpretation and may be opaque to stakeholders without specialist knowledge. In
Externí odkaz:
https://doaj.org/article/d53504fefaa245b3a48dba683b6a4396
Publikováno v:
npj Science of Food, Vol 6, Iss 1, Pp 1-9 (2022)
Abstract The composition of honey, a complex natural product, challenges analytical methods attempting to determine its authenticity particularly in the face of sophisticated adulteration. Of the advanced analytical techniques available, only isotope
Externí odkaz:
https://doaj.org/article/206befb13c0c4cfba2a82322221271e7
Autor:
P, Andreo, D T, Burns, R P, Kapsch, M, McEwen, S, Vatnitsky, C E, Andersen, F, Ballester, J, Borbinha, F, Delaunay, P, Francescon, M D, Hanlon, L, Mirzakhanian, B, Muir, J, Ojala, C P, Oliver, M, Pimpinella, M, Pinto, L A, de Prez, J, Seuntjens, L, Sommier, P, Teles, J, Tikkanen, J, Vijande, K, Zink
Publikováno v:
Physics in medicine and biology. 65(9)
The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new b
A key comparison has been made between the air-kerma standards of the NRC and the BIPM in mammography x ray beams. The results show the standards to be in agreement at the level of the combined standard uncertainty of 3.2 parts in 103. The results ar
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::828296e61b72dd1a858dbb9b22f14fce
https://doi.org/10.1088/0026-1394/57/1a/06011
https://doi.org/10.1088/0026-1394/57/1a/06011
Publikováno v:
Metrologia. 59:06022
Main text A key comparison has been made between the air-kerma standards of the ARPANSA, Australia, and the BIPM in the low-energy x ray range. The results show the standards to agree at the level of the expanded uncertainty of the comparison of 9 pa
Publikováno v:
Metrologia. 59:06011
Main text A key comparison has been made between the air-kerma standards of the KRISS, Republic of Korea, and the BIPM in the low-energy x-ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the co
Publikováno v:
Metrologia. 59:06014
Main text A key comparison has been made between the air-kerma standards of the GUM, Poland, and the BIPM in the low-energy x-ray range. The results show the standards to be in agreement at the level of the expanded uncertainty of the comparison of 5
Publikováno v:
Metrologia. 59:06010
Main text A key comparison has been made between the absorbed dose to water standards of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and the BIPM, in accelerator photon beams. The results show the standards to be in agreement within the
Publikováno v:
Metrologia. 59:06005
Main text A key comparison has been made between the absorbed dose to water standards of the National Research Council of Canada (NRC), Canada and the BIPM in accelerator photon beams. The results show the standards to be in agreement within the stan
Publikováno v:
Jordan Journal of Pharmaceutical Sciences. 10:1-12