Zobrazeno 1 - 10
of 12
pro vyhledávání: '"D. N. Fry"'
This report provides an overview of recent advances in portable electric power source (PEPS) technology and an assessment of emerging PEPS technologies that may meet US Special Operations Command`s (SOCOM) needs in the next 1--2- and 3--5-year time f
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7de3dedc855e6a75269961eb88583c1a
https://doi.org/10.2172/663584
https://doi.org/10.2172/663584
This report discusses research being conducted in the following areas: reactor systems; research instruments; measurement and controls engineering; and technical support.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b1b43c8ff42532f138a2a2fdc208a029
https://doi.org/10.2172/10138003
https://doi.org/10.2172/10138003
Autor:
S. I. Abdel-Khalik, R. W. Conn, G. A. Moses, K. H. Sun, R. B. Duffey, David A. Ehst, Kenneth Evans, Weston M. Stacey, D. N. Fry, R. C. Kryter, M. V. Mathis, J. E. Mott, J. C. Robinson, S. Banerjee, F. W. Barclay, D. A. Orth, Thomas Michael Gilliam, Helmut Elbel, José López Jiménez, D. Haas, J. Van de Velde, H. Braun, Robert A. Fjeld, Robert Jennings Heinsohn, Samuel H. Levine
Publikováno v:
Nuclear Technology. 43:1-4
Publikováno v:
IEEE Transactions on Nuclear Science. 21:750-756
Pattern recognition methods were applied to analyze and interpret neutron noise data from the High Flux Isotope Reactor (HFIR) at ORNL. The results show that it is feasible to detect some core component failures by means of machine-discemible differe
Publikováno v:
Annals of Nuclear Energy. 2:341-351
Neutron noise signatures were obtained on August 3, 1973, that were due to abnormal movement of the core barrel at the Palisades Nuclear Plant. Frequency spectra, rms noise, and amplitude probability density were recorded as sensed by ex-core and in-
Publikováno v:
IEEE Transactions on Nuclear Science. 18:345-350
Analysis of neutron fluctuations produced by coolant pressure oscillations and of neutron noise were investigated as two possible boiling detection methods during a boiling experiment in the High Flux Isotope Reactor (HFIR). Neither method detected b
Autor:
J. C. Robinson, D. N. Fry
Publikováno v:
Nuclear Science and Engineering. 42:397-405
Autor:
Reino Ekholm, T. Shimooke, D. N. Fry, P. A. Haas, G. T. Colwell, C. L. Williams, J. C. Hsu, G.E. Zevallos, D. W. Stevens, Prodyot Roy, Gary P. Wozadlo, Günter H. Lohnert, Richard T. Schneider, Norman A. Frigerio, Leo L. LaVoy, D. L. Hollis, H. A. Das, J. Zonderkuis, F. J. Salzano, L. Newman, M. R. Hobdell, R. L. French, I. G. Mooney, H. O. Menlove, R. H. Avgustson, Darryl B. Smith, M. A. Schultz, Wayne F. Eckley, Donald J. Dudziak
Publikováno v:
Nuclear Technology. 10:244-248
Publikováno v:
IEEE Transactions on Nuclear Science. 19:828-836
The power-to-reactivity frequency response of the High-Flux Isotope Reactor (HFIR) was measured over the range 0.01 to 5 Hz using periodic binary input signals introduced with normal system control rods. These results served to validate the theoretic