Zobrazeno 1 - 10
of 30
pro vyhledávání: '"D. Molenda"'
Autor:
M. Schuppmann, H. Theado, S. Youssef, O. Stawicki, D. Molenda, P. Stopp, S. Pushkarev, W. Bähr, J. Wagner
Publikováno v:
Tagungsband.
Publikováno v:
Journal of the American Medical Directors Association. 20:B22-B23
Publikováno v:
Applied Physics Letters. 80:1331-1333
We introduce a method for a simultaneous topographical and optical characterization of aperture probes for scanning near-field optical microscopy which is based on imaging of small sized fluorescent nanospheres (∼20 nm). The near-field optical fluo
Publikováno v:
Optics express. 13(26)
A triangular nano-aperture in an aluminum film was used as a probe in a scanning near-field optical microscope (SNOM) to image single fluorescent molecules with an optical resolution down to 30 nm. The differently oriented molecules were employed as
Publikováno v:
Applied Physics B-Laser and Optics
Applied Physics B-Laser and Optics, Springer Verlag, 2006, 84 (1-2), pp.49-53. 〈10.1007/s00340-006-2296-9〉
Applied Physics B-Laser and Optics, Springer Verlag, 2006, 84 (1-2), pp.49-53. 〈10.1007/s00340-006-2296-9〉
International audience; We recently found that the intensity of the electric near field of a triangular aperture in a metal film is strongly localized at one edge of the aperture for incident light polarized perpendicular to this edge. Previous numer
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c6b3c6b6057a73d7a63bd2f8d2cf4b8f
https://hal.archives-ouvertes.fr/hal-00437590
https://hal.archives-ouvertes.fr/hal-00437590
Publikováno v:
2005 Quantum Electronics and Laser Science Conference.
We demonstrate that scanning near-field optical microscopy based on a probe with a triangular aperture is capable of imaging single fluorescent molecules with an optical resolution of 30 nm. Numerical simulations agree well with experiment.
Publikováno v:
Physical Review B. 72
We have recently demonstrated that the electric near-field emerging from a triangular aperture at the tip of a metal-coated tetrahedron of glass exhibits a highly confined and intense spot when the light incident from within the glass body is polariz
Publikováno v:
Journal of microscopy. 210(Pt 3)
The applications of scanning near-field optical microscopy to biological specimens under physiological conditions have so far been very rare since common techniques for a probe-sample distance control are not as well suited for operation in liquid as
Autor:
Christiane Höppener, Harald Fuchs, A. Naber, N. Lu, D. Molenda, Ulrich C. Fischer, H.-J. Maas
Publikováno v:
Physical Review Letters. 89
We present a probe concept for scanning near-field optical microscopy combining the excellent background suppression of aperture probes with the superior light confinement of apertureless probes. A triangular aperture at the tip of a tetrahedral wave
Publikováno v:
Protection of Materials and Structures from the Low Earth Orbit Space Environment ISBN: 9789401060042
Total and diffuse reflectance measurements together with scanning electron microscopy analysis performed on samples of Teflon® FEP, textured by a novel ion-beam process, confirmed formation of surfaces with highly diffuse properties. At the same, me
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::434b6910bf0417a76dddca74e37aa693
https://doi.org/10.1007/978-94-011-4768-2_14
https://doi.org/10.1007/978-94-011-4768-2_14