Zobrazeno 1 - 10
of 102
pro vyhledávání: '"D. Limagne"'
Autor:
R.C. Martins, A.R. Ramos, D. Limagne, F. Giuliani, M. Felizardo, T. Morlat, José G. Marques, Georges Waysand, T.A. Girard
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008, 585 (1-2), pp.61-68. ⟨10.1016/j.nima.2007.11.018⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2008, 585 (1-2), pp.61-68. ⟨10.1016/j.nima.2007.11.018⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008, 585 (1-2), pp.61-68. ⟨10.1016/j.nima.2007.11.018⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2008, 585 (1-2), pp.61-68. ⟨10.1016/j.nima.2007.11.018⟩
International audience; The application of Superheated Droplet Detectors in dark matter searches by the SIMPLE project uses an acoustic instrumentation sensitive to the shock wave generated by the bubble nucleation of the refrigerant droplets. Previo
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2006, 560 (2), pp.339-345. ⟨10.1016/j.nima.2005.12.202⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006, 560 (2), pp.339-345. ⟨10.1016/j.nima.2005.12.202⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2006, 560 (2), pp.339-345. ⟨10.1016/j.nima.2005.12.202⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006, 560 (2), pp.339-345. ⟨10.1016/j.nima.2005.12.202⟩
International audience; The lifetime of a Superheated Droplet Detector (SDD) is limited by the fracture of the gel matrix, due to the growth of the bubble in time caused by Oswald ripening. There are several approaches to increasing the lifetime of a
Autor:
F. Giuliani, A. C. Fernandes, C Oliveira, J Marques, Georges Waysand, A.R. Ramos, D. Limagne, M. Felizardo, T. Morlat, T.A. Girard
Publikováno v:
Radiation Protection Dosimetry
Radiation Protection Dosimetry, 2005, 115 (1-4, 1, SI), pp.398-402. ⟨10.1093/rpd/nci124⟩
Radiation Protection Dosimetry, Oxford University Press (OUP), 2005, 115 (1-4, 1, SI), pp.398-402. ⟨10.1093/rpd/nci124⟩
Radiation Protection Dosimetry, 2005, 115 (1-4, 1, SI), pp.398-402. ⟨10.1093/rpd/nci124⟩
Radiation Protection Dosimetry, Oxford University Press (OUP), 2005, 115 (1-4, 1, SI), pp.398-402. ⟨10.1093/rpd/nci124⟩
10th International Conference on Radiation Shielding (ICRS-10)/13th ANS Topical Meeting on Radiation Protection and Shielding (RPS 2004), Funchal, PORTUGAL, MAY 09-14, 2004; International audience; SIMPLE is a superheated droplet detector (SDD) exper
Autor:
C Oliveira, A.R. Ramos, D. Limagne, F. Giuliani, J. I. Collar, T. Morlat, José G. Marques, G. Waysand, T.A. Girard
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 526:348-358
We report measurements of the response of large-volume superheated droplet detectors for the SIMPLE project to filtered monochromatic neutron beams of energies 54 and 149 keV. The results continue to indicate a significantly higher than anticipated r
Autor:
Georges Waysand, J. Salgado, C Oliveira, D. Limagne, T.A. Girard, T. Morlat, José G. Marques, F. Giuliani, J. I. Collar
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 213:172-176
We report an MCNP study of filtered monochromatic neutron beams of energies 25, 54 and 149 keV for response studies of a superheated droplet detector for the SIMPLE experiment. The results identify the importance of the detector temperature stabilizi
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Physica C: Superconductivity. 377:121-129
Flux expulsion in a type-I superconducting strip, induced by decrease of a perpendicular magnetic field following field increase-induced flux penetration, is observed by real time detection of the flux-induced voltage pulses. Three different expulsio
Publikováno v:
Physical Review Letters
Physical Review Letters, 2000, 85 (15), pp.3083-3086. ⟨10.1103/PhysRevLett.85.3083⟩
Physical Review Letters, 2000, 85 (15), pp.3083-3086. ⟨10.1103/PhysRevLett.85.3083⟩
We report on the fabrication aspects and calibration of the first large active mass ($\sim15$ g) modules of SIMPLE, a search for particle dark matter using Superheated Droplet Detectors (SDDs). While still limited by the statistical uncertainty of th
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 444:84-87
Geometrically metastable detectors consist of macroscopically thin superconducting metallic lamina held in a perpendicular magnetic field, which admit flux under irradiation. We describe their performance aspects, and present measurements of the 187
Autor:
C Chen, A. Chan, P Bonierbale, J. I. Collar, R Bruère-Dawson, D. Limagne, Georges Waysand, C. Y. Huang, P. Perrier, T.A. Girard, S. R. Hou, Yuan-Hann Chang, P. K. Teng, Yong Jin, V. Jeudy, Luke C. L. Yuan, S.C. Lee
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 444:289-292
A compact multichannel Superheated Superconducting Grain detector (SSG) has been irradiated by the T9 beam (mostly composed by high energy electrons) of the SPS machine at CERN. The SSG detector consists of a set of cylindrical suspensions of tin gra